Ramset “intelligate” control board, Introduction – Controlled Products Systems Group RAM5000 User Manual

Page 16

Advertising
background image

14

RAMSET

www.ramsetinc.com

RAM 5000 • 5100 • 5200

plug-in

Power Transformer

40VA.

Dipswitches

Automatic Timer, Prewarn,

Constant Warning, Secure Close,

Full Reverse ERD, Radio Cycle,

One Pass, Low / High ERD,

Adjustment, Close Delay,

Open Delay and Left / Right.

Relay Connections

Indicator lights, alarms and sirens.

Reverse Loop

Exit Loop

Phantom Loop

Microprocessor

Reprogrammable, controls

all functions of the operator.

ERD

Self adjusting, with low

and high adjustments.

3 Button Station

Open - Stop - Close

Foot Pedal Plug

Stops the motor from running

while the foot pedal is engaged.

Master / Slave Plug

Synchronizes movement between two

gates. 3 wires (A-, B- and Common).

Standard Connections

Reverse Loop, Fire Box, Exit Loop,

Phantom Loop, Radio, Edge Sensor,

24 VAC and Magnetic Lock.

3 Button Station

plug-in

JP10

JP9

JP3

JP11

JP7

plug-in

JP2

RAMSET “INTELLIGATE” CONTROL BOARD

Introduction:

Ramset’s “Intelligate” Control Board works

with Sliding, Swinging and Overhead vehicular

gate operators. It is controlled by a program-

mable microprocessor that reads and precisely

executes all functions of the Control Board.

The Control Board is powered by a separate

mounted 24 VAC transformer. This allows no

necessary board modifications between 110


VAC and 220 VAC single-phase applications.

Some of the functions of the Control Board

are: 0 - 60 seconds automatic close timer, self

adjusting E.R.D. with low and high setting,

constant warning, prewarning, secure close,

one pass, open & close delay, left/right hand

operation, plug-in loop detectors and RS485

three wire master/slave connection.

Figure 13