Direct Burial Installation Instructions*

Preformed direct burial installation tips and directions

This is not a Saw-Cut Loop

for all saw-cut applications use

BD

Loops

preformed 3/16” saw-cut loop.

Installation in

Concrete

See Reverse side of this page.

(Pictures included)

Installation Under

Pavers

If the sub-base is concrete or
a slurry do not use this loop.
Saw-Cut in a loop instead.


Determine loop position and
footprint to include lead-in run to
gate operator. Be sure to use the
correct loop size.

*


Dig a 2” wide by 3-4” deep
trench in the pattern of the loop
and lead-in. (See Figure 1)

Fill Trench with one inch of sand.

Place loop in trench and run
lead-in through

½” schedule 40

or 80 rigid PVC. Glue all PVC
joints with a

a proper PVC

solvent cement

.


Cover loop and lead-in PVC run
with 2½” of sand.





Installation under

Asphalt

Position and shape the loop on
sub-base. Be sure to use the
correct loop size.

*

Pull lead-in through ½

” schedule

40 or 80 rigid PVC. Glue all PVC
joints with a

a proper PVC

solvent cement

.


Dig a

2” wide by 3-4” deep trench

in the size and place of the loop
footprint and lead-in.

Fill the trench with one inch of
sand base.

Lay the loop and lead-in run in the
trench on top of sand base and
use supplied ground stakes to
secure the loop corners.

Cover loop and lead-in PVC run
with 2½

” of sand.

Installation in

Gravel Road

Position and shape the loop on
sub-base. Be sure to use the
correct loop size.

*

Pull lead-in through ½

” schedule

40 or 80 rigid PVC. Glue all PVC
joints with a

a proper PVC

solvent cement

.


Dig a 7

” to 10” deep trench in the

size and place of the loop
footprint and lead-in.

Fill the trench with one inch of
sand base.

Lay the loop and lead-in run in the
trench on top of sand base and
use supplied ground stakes to
secure the loop corners.

Cover loop and lead-in PVC run
with 2½

” of sand. Compact sand

around the loop then fill in with
road base.


Harness Wire: Solder all connections


Plug/Screw Connectors: Tint all connections

Basic loop layout guidelines to follow

Reverse and Exit Loops

4ft from the gate/door.

Swing gates require 3ft from its
complete open and closed position.

2ft from each curb.

4ft from every other loop.

Shadow loops

Loop lies under the swing path.

3-4ft from the gates in its complete open
and closed position.

0-2ft from the curb. (Single Swing Gate)

Detection height is determined by approximately 2/3 of the short leg of the loop. Residential 4ft short leg (Detection of standard size

vehicles only).

Commercial 6ft short leg (Detect higher bed vehicles).

*Check BDLoops.com for the latest installation instructions

Loop should

be encased in

sand.

Soil

Loop

Sand

Figure 1

The ground stakes included with the loop are to help
hold the loop down while laying out a trench pattern.
When the loop is placed in the trench the ground stakes
are no longer necessary and should be discarded.