Wiring Diagram #1 Wiegand to Serial

The Wiegand to RS232 converters support incoming commands to
control the Reader LED and Converter Relay.

RX Data:

NOTE: Commands must be capitalized characters
Turn LED on................

@ L 1

Turn LED off...............

@ L 0

Toggle LED.................

@ L 2

(Bi-Color LED Turns Orange)

Turn Relay on..............

@ R 1

Turn Relay off.............

@ R 0

CVX Terminal

DB9 Pin

Ground

5

RS232 Input

3

RS232 Output

2

DB-9 Connections
Direct to PC Com Port

Connections

to Serial

Device

D0/Clock In
D1/Data In
LED Out
Ground
RS232 Input
RS232 Output

Ground

+8 to +16 VDC In

Data Bender®

Card

Reader

Data0
Data1
LED
Ground

DC

Power

Supply

(-)

(+)

Reader powered by external supply (8 to 16 VDC)