Delta-3 Series

DRA

DIGITAL RECEIVER

Installation Instructions

(800) 421-1587

www.linearcorp.com

DESCRIPTION

The Delta-3 DRA receiver is a small economical unit designed for commercial
gate and door access control. It is compatible with solid state control boards.
Upon receipt of a properly coded signal from a transmitter, it provides a switch
operation for both NO and NC circuits. Any Delta-3 transmitter may be coded
to activate this receiver, and any number of transmitters may be used to
operate this receiver. In addition, the DRA may be programmed to respond
to one of 256 digital codes.
In order to avoid the possibility of duplicating codes in adjacent systems, the
factory set codes should not be used. In addition, among the valid codes
available, four others should not be used because they are too often
duplicated. These include: (1) all keys set to ON, (2) all keys set to OFF, (3)
keys set in alternating ON-OFF positions, and (4) keys set in alternating
OFF-ON positions.
Where a number of receivers are to be installed in close proximity (as in an
apartment complex), install such receivers at least 10 feet apart. If receivers
are installed closer than 10 feet apart, blocking may occur.

STEP 1A

Receiver code setting. Locate the receiver coding

switch which is recessed in the back of the receiver case. To set
a code, select any valid combination of ON and OFF positions for
the switch keys numbered 1 through 8. Use a paper clip to set
the eight keys on your receiver.

STEP 1B

Transmitter code setting. Locate the coding

switch on the transmitter and set the eight keys identical to those
on the receiver. Be sure they are both coded from left to right!
Be sure they are identical! If using a two or four-channel
transmitter refer to the coding instructions included with the
transmitter for proper system coding.

STEP 2A

C o n n e c t i n g r e c e i v e r ( U s i n g t r a n s f o r m e r

power). A Model T12A transformer can be used to power the
receiver when connecting receiver to any operator. Connect as
shown, then plug the transformer into a convenient (unswitched)
120 VAC outlet.

STEP 2B

Connecting receiver (using operator power).

Connect the receiver to the garage door or gate operator as
shown in the diagram. Power will be supplied from the operator.

STEP 3

Optional receiver mounting bracket. A mounting

clip is packaged with each receiver. To install the receiver, attach
the clip to the mounting surface with screws. Position the two
rectangular holes on the back of the receiver over the clip and
snap the receiver down into place.

STEP 4

Test receiver.

Be sure the door or gate area is clear.

Activate each transmitter and verify that the receiver triggers the
operator. If desired, a continuity meter may be used to test the
relay contact closure.

LIMITED WARRANTY

This product is warranted to the consumer against defects in material and workmanship for one year
from the date of purchase. This warranty applies to first retail buyers of new devices. Warrantor will
repair, or at its option, replace, any device it finds that requires service under this warranty, and will
return the repaired or replaced device to the consumer at the warrantor’s cost. For warranty service
and shipping instructions contact warrantor at the address shown below. Devices must be sent to
warrantor for service at owner’s expense. The remedies provided by this warranty are exclusive. Implied
warranties under state law are limited to the one year period of this written warranty. Some states do
not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to
you. In order to be protected by this warranty, save your proof of purchase and send copy with equipment
should repair be required. This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
All products returned for warranty service require a Return Product Authorization Number (RPA#).
Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

IMPORTANT !!!

Linear radio controls provide a reliable communications link and fill an important need in portable
wireless signaling. However, there are some limitations which must be observed.

For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as
Part 15 devices. As such, they have limited transmitter power and therefore limited range.

A receiver cannot respond to more than one transmitted signal at a time and may be blocked by
radio signals that occur on or near their operating frequencies, regardless of code settings.

Changes or modifications to the device may void FCC compliance.

Infrequently used radio links should be tested regularly to protect against undetected interference
or fault.

A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.

Copyright © 1999 Linear Corporation

200103 D

SWITCHES IN
TRANSMITTER

THIS SWITCH
HAS 2, 3 & 6 ON

REMOVE BATTERY
ACCESS DOOR

CODING
SWITCH

SWITCHES IN
RECEIVER

THIS SWITCH
HAS 6, 3 & 2 ON

POWER INPUT
WIRE

CODING SWITCH

N

/C

N

/O

C

O

M

.

N/C N/O

COM.

MOUNTING CLIP

RECEIVER

MOUNTING

BRACKET

MOUNTING HOLES

ON RECEIVER

COM

NO

NC

T12A

TRANSFORMER

RADIO

RECEIVER

MANUAL

PUSHBUTTON

GARAGE DOOR

OPERATOR

COM

NO

NC

3 (+)

1 (-)

2 Relay

NOTE:
OPERATOR
MUST SUPPLY
11-24 VDC OR
12-16 VAC

12 VOLT

OPERATOR

MANUAL

PUSHBUTTON

GOLD

SILVER

RADIO POWER
12 VOLTS

RADIO
RECEIVER

P R E S S T R A N S M I T T E R

B U T T O N T O T E S T

W A R N I N G !

B E S U R E D O O R O R

G A T E A R E A S A R E C L E A R

O F O B S T R U C T I O N S

Advertising