Troubleshooting




Test Loop and Gate Operation

Technical Support

Diagram 9. Incorrect installation

Table 2. Troubleshooting Tips

Symptoms

Problem

Resolution

Intermittent detection.
False vehicle loop detec-
tion where gate seems to
be detecting ghost images
or signal is not reaching
HY-5A detector.

HY-5A detector is not seated
properly into the Controller board.
Symptoms can also occur when the
HY-5A detector is seated improper-
ly during installation. Do NOT flex
the module into place. See
Diagram 9. Refer to Diagram 5 for
the correct orientation. The HY-5A
module remains undamaged but
the socket on the Controller board
has been loosened or damaged.

1. Reseat and reinitialize the HY-5A

detector by following steps 2
through 6 in Install HY-5A Vehicle
Detectors
on page 2.

2. Run both tests discussed in Test the

Vehicle Loop on page 1.

3. If the problem is not resolved,

check for a damaged Controller
board connection. Replace the
board, if necessary. Call Technical
Support.

Gate does not always
open or close when a
vehicle crosses the
obstruction loops

.

Most likely, the HY-5A detectors
were connected to the Controller
board as a group and then initial-
ized.

Individually install each HY-5A module.
Wait until the indicator light turns off
before and press the Reset button
before installing the next HY-5A detec-
tor.

No indicator light appears
on the HY-5A detector.

The HY-5A detector is installed
backwards or it could be defective.

Check the orientation of the HY-5A
detector and re-install it, if necessary.

CAUTION: Do NOT
flex or wiggle the
HY-5A detector.

The socket can be
damaged if the
HY-5A detector is
improperly installed.

Diagram 10. Incorrect installation

The indicator
will not light
if the HY-5A
detector is
installed
backwards.