Impulse AEV-6356 User Manual

Aev-6356, Environment test, Features specifications

Advertising
background image

12-1

12

Environment Test

AEV-6356

Intel® Core™ i7-3517UE or Celeron® 847E Onboard

EN50155 Certification

Well-protection:

Isolation 1 x RS-422/485/ Power (OVP/ LVP/ SCP)
Easy-to-control:

Isolation 6x Digital Input + 2x Digital Output
Wireless Solution: WiFi / 3G / GPS
Rugged M12 Connector for LAN/ Serial/ USB/ Power

Railway Box PC With Onboard Intel® Core™ i5/ Celeron® M Processor

System

Processor

Intel® Core™ i7-3517UE up to 2.8GHz, Intel® Celeron® 827E ,1.4 GHz

Chipset

Intel® QM77

System Memory

DDR3 SODIMM x 1, Max.8GB

Display Interface

DB-15 x 1 for VGA
DVI-I x 1

Storage Device

CFast™ x 1, SATA 3 x 2 (Support RAID 0,1)

Front I/O connector

USB 2.0 x 2 (M12), RS-232/422/485 x 1 (M12), Giga LAN x 2 (M12), VGA x 1
(DB-15), DVI-I x 1, Power button, CFast slot x 1, SIM slot x 1

Rear I/O connector

Digital Input x 6, Digital Output x 2, USB 3.0 x 2 (Type A), RS-232 x 2 (DB-9),
RS-232/422/485 x 1 (DB-9, Isolation), Line-out x 1, Mic x 1, Power input
(18~75VDC) (M12)

Digital Input

Digital Input x 6
Digital Output x 2
USB 3.0 x 2 (Type A)
RS-232 x 2 (DB-9)
RS-232/422/485 x 1 (DB-9, Isolation)
Line-out x 1
Power input (18~75VDC) (M12)

Digital Output

Output Channels: 2, sink type
Output Current: Max. 200 mA per channel
On-state Voltage: 24 VDC nominal, open collector to 30 VDC
Connector Type: 10-pin screw terminal block (6 DI points, 2 DO points, DI
Source, GND)
Isolation: 3 KV optical isolation

Serial Interface

RS-485: isolation 3000VDC (Rear I/O)

Expansion Slot

PCIe Mini card x 2 (WiFi / 3G / GPS) (Option)

Indicator

System LED x 1

OS Support

WinCE 6.0, Window® XP Embedded,
Window XP, Window® 7, Window® Embedded Standard 7, Linux Fedora

Mechanical

Mounting

Wall / Din-rail

Dimension

Gross Weight

Net Weight

Power Supply

DC Input

DC 18~75V (M12)
Over-voltage protection
Low-voltage protection
Short circuit protection

System

Operation Temperature

-40°C to 70°C

Humidity

Conforms to EN 50155/EN50125-1, Test method EN 60068-2-30 (variant 1):
Yearly average at 75 % HR, 30 days at 95 % HR, Occasionally at 100 % HR
Tropicalisation and mist constraints

Altitude

<2500meters

Salt Mist

Conforms to EN50155

Insulation Resistance

Conforms to EN50155

Voltage withstand

-Conforms to EN50155,
-Power supply voltage range conforms to Italian standard ST306158 0,6<U/
Un<1,5
-Power supply variation conforms to Italian SCMT 0,6<U/Un<1,67 during 0,1sec
-Power supply voltage switching (EN 50155 § 3.1.3) Class C1: 100 ms (0.6 Un
during 100 ms of the battery at Un)

Mechanical Earth
Continuity

Conforms to Standard STM-E-001
Acceptance criteria = R<100 m

Ω

Every metallic part accessible to the user must be connected to the mechanical
earth (NF F 60100)

Pollution

Compliant with : EN60721-3-5 standard

EMC

Compliant with EN50121 standard

ESD

Conforms to EN 50155

Expansion Slot

PCIe Mini Card x 2

Radiated Electromagnetic
Fields

Radiated immunity Test method EN 61000-4-3: The frequency range for the
tests shall be done until 2.4 GHz, and an attenuation of 20 V/m.

Immunity To Fast
Transients Bursts

Conforms to Standard reference : EN 50155 (§ 10.2.7) / EN 50121-3-2
Fast transient burst immunity, Test method EN 61000-4-4, ± 2,6 kV- repetition
frequency: 5 kHz, ports referenced to the battery: direct injection, other signals:
capacitive coupling.

Surges Immunity

Standard reference : EN 50155 (§ 10.2.6.2) / EN 50121-3-2
Surge immunity, Test method EN 50155 (§ 10.2.6.2), Waveform A:±1.8 kV (5-
50µs, 5ohm) on the battery reference ports, Waveform B: ± 8.4 kV (0,05 µs -0,1
µs, 100 ohm) on the battery reference ports.

Conducted Disturbances
Induced By Radio-
Frequency Fields

Test method EN 61000-4-6, 150kHz-80MHz 1kHz, 80%AM, 10 Vrms

Emission Measurement

Conducted emissions Standard reference : EN 50155 (§ 10.2.8.2) / EN 50121-
3-2
Radiated emission, Test method EN 55011, Class A, 30MHz-230MHz 40dBµV,
230MHz-2.4GHz 47dBµV.

Protection Against
Electrical Hazards

PD2 environment as defined in EN50124
Over-Voltage degree (OV2)Rationale : It is not acceptable to always export the
constraints on rolling stock as other signalling suppliers propose a solution into
a box.

Fire And Smoke

conforms to NF F 16101 for cables and NF F 16102 for equipment

Shocks And Vibrations

Test method EN 61373 (random vibration), Operating test (duration > 10 min),
Frequency range = 5-150 Hz, 0,7 m/s2 (longitudinal & transversal axis), 1 m/s2
Test method EN 61373 (random vibration), Frequency range = 5-150 Hz, Test
with equipment powered down for 5 hr, 5,5 m/s2 (longitudinal & transversal
axis).
Test method EN 61373 (random vibration), 50 m/s2 for 30 ms (longitudinal &
transversal axis), 30 m/s2 for 30 ms (vertical axis), 3 shocks x 2 directions x 3
axes = 18 shocks

Front View

Rear View

DIO

USB3.0 x 2

Audio Out

Antenna

Antenna Hole

COM

VGA

CFast™/SIM

Power Button

DVI

COM

RS-232/222/485

USB x 2

LAN

COM x 2

DC-In

Features

Specifications

In

-V

eh

ic

le E
m

be

dde

d Co

nt

ro

lle

r S

olu

tio

ns

Advertising