Impulse DSCT47 User Manual

Dsct47, Linearized thermocouple input transmitters, Dsct

Advertising
background image

DIN Rail Mount Two-WireTransmitters

DSCT

For information call 800-444-7644

210

DSCT47

Linearized Thermocouple Input Transmitters

Figure 1: DSCT47 Block Diagram

Features

• Interfaces to Types J, K, T, E, R, S, B, and N

Thermocouples

• Linearizes Thermocouple Signal
• Process Current Output
• 1500Vrms Transformer Isolation
• ANSI/IEEE C37.90.1 Transient Protection
• Input and Output Protected to 240VAC

Continuous

• Up to 60V Loop Voltage
• 160dB CMR
• 85dB NMR at 60Hz, 80dB at 50Hz
• ±0.10% Accuracy
• Easily Mounts on Standard DIN Rail
• CSA and FM Approvals Pending
• CE Compliant

Description

Each DSCT47 thermocouple input transmitter provides a single channel of

thermocouple input which is filtered, isolated, amplified, linearized, and

converted to a process current output (Figure 1). Signal filtering is accomplished

with a five-pole filter, which provides 85dB of normal-mode-rejection at 60Hz

and 80dB at 50Hz. An anti-aliasing pole is located on the field side of the isolation

barrier, and the other four are on the process loop side. After the initial

field-side filtering, the input signal is chopped by a proprietary chopper circuit.

Isolation is provided by transformer coupling, again using a proprietary

technique to suppress transmission of common mode spikes or surges.
Linearization is achieved by creating a non-linear transfer function through the

module itself. This non-linear transfer function is configured at the factory and

is designed to be equal and opposite to the thermocouple non-linearity.
The DSCT47 can interface to eight industry standard thermocouple types: J,

K, T, E, R, S, B and N. Each transmitter is cold-junction compensated to correct

for parasitic thermocouples formed by the thermocouple wire and screw

terminals on the transmitter. Upscale open thermocouple detection is provided

by circuitry. Downscale indication can be implemented by installing a 47M

,

±20% resistor between screw terminals 6 (+IN) and 8 (-EXC) on the input

terminal block.
Special input and output circuits on the DSCT47 transmitters provide protection

against accidental connection of power-line voltages up to 240VAC and against

transient events as defined by ANSI/IEEE C37.90.1. Loop power lines are

secured to the module using screw terminals, which are in pluggable terminal

blocks for ease of system assembly and reconfiguration. Transmitter zero and

span settings are adjustable up to ±3%. The adjustments are made using

potentiometers located under the front panel label and are non-interactive for

ease of use.

Advertising