Page 2: Ordering information

Advertising
background image

Visit our website www.dataforth.com

109

SensorLex

®

8B Isolated Analog Signal Conditioning Products

8B

8B

©1995-2009 Dataforth Corporation, All Rights Reserved ISO9001:2000-Registered QMS

Specifications

Module

8B33

Typical at T

A

=+25°C and +5V power

Ordering Information

Model

Input Range

Output Range

8B33-01

0mV to 100mV

0V to +5V

8B33-02

0V to 1V

0V to +5V

8B33-03

0V to 10V

0V to +5V

8B33-04

0V to 100V

0V to +5V

8B33-05

0V to 300V

0V to +5V

8B33-06

0A to 1A

0V to +5V

Input

Signal Range

100mV to 300Vrms, 0 to 1Arms

Standard Frequency Range

45Hz to 1000Hz

Extended Frequency Range

1kHz to 10kHz

Impedance

499K

Ω (-01, -02)

1M

Ω (-03, -04, -05)

.05

Ω (-06)

Coupling

AC

Protection

(1)

Continuous (-01 thru -05)

350Vrms

Continuous (-06)

2Arms

Transient (-01 thru -05)

ANSI/IEEE C37.90.1

Transient (-06)

See note 2

Output

Signal Range

0V to 5V

Voltage Limit

±9V

Protection

Continuous Short to Ground

Ripple and Noise

0.0375% Span rms

Accuracy (10-100% Span)

(3) (4)

Sinusoid

50/60Hz

±0.25% Span

45Hz to 1kHz

±0.625% Span

1kHz to 10kHz

±1.375% Span, ±3.25% Span(-06)

Non-Sinusoid

Crest Factor = 1

±0.25% Span

Crest Factor = 2

±0.325% Span

Crest Factor = 3

±0.475% Span

Crest Factor = 4

±0.7% Span

Vs. Temperature

±100ppm/ºC

Isolation (Common Mode)

Input to Output, Input to Power
Continuous

1500Vrms max

Transient

ANSI/IEEE C37.90.1

CMR (50Hz to 60Hz)

120dB

NMR

70dB at 60Hz

Response Time, 90% Span

<120mS

Supply Voltage

+5VDC ±5%

Current

30mA

Sensitivity

±200ppm/%

Environmental

Operating Temperature Range

–40ºC to +85ºC

Storage Temperature Range

–40ºC to +85ºC

Relative Humidity

0 to 90% Noncondensing

Emissions EN61000-6-4

ISM, Group 1

Radiated, Conducted

Class A

Immunity EN61000-6-2

ISM, Group 1

RF

Performance A ±0.5% Span Error

ESD, EFT, Surge, Voltage Dips

Performance B

Dimensions

1.11" x 1.65" x 0.40"

(28.1mm x 41.9mm x 10.2mm)

NOTES:
(1) 8B33 and 8BP01, 8BP02, 8BP04, 8BP08, 8BP16, XEV rating only. Backpanels obtained from

other sources may have lower ratings.

(2) For 1 to 25 seconds the max allowable transient current rating is

√2500/(event time). For less

than 1 second, ANSI/IEEE C37.90.1 applies with a 0.05

load. For greater than 25 seconds, the

2 Arms continous rating applies.

(3) At standard 60Hz factory calibration. Consult factory for calibration at other frequencies.
(4) For 0-10% Span measurements, add 0.25% accuracy error (-02 through -07) or 1.00% accuracy

error (-01). Accuracy includes linearity, hysteresis and repeatability but not source or external
shunt inaccuracy (if used).

Advertising