Programming the dio-32.pci, Programming for windows, Programming for linux – Impulse 8004e User Manual

Page 14: Digital i/o interface, Rogramming for, Indows, Inux, Igital, Nterface

Advertising
background image

Programming the DIO-32.PCI

Sealevel’s SeaI/O Classic software is provided to assist in the development of
reliable applications for the Sealevel Systems family of PCI and PCI Express digital
I/O adapters. The SeaI/O Classic software is included on the CD that shipped with
the board. The software contains driver functions for use in accessing the I/O as well
as helpful samples and utilities.

Programming for Windows

The SeaI/O Classic API (Application Programmer Interface) provides a variety of
useful high-level function calls implemented in a Windows dynamic link library
(DLL). The API is defined in the help file (Start/Programs/SeaIO/SeaIO Help)
under “Application Programmers Interface”. This help file also includes detailed
information dealing with installation / removal of the software and information
about latency, logic states, and device configuration.
For C language programmers we recommend using the API to access the DIO-
32.PCI. If you are programming in Visual Basic, using the ActiveX control
included with SeaI/O is advised.

Samples and Utilities

A variety of sample programs and utilities (both executable and source code) are
included with SeaI/O. Further documentation on these samples can be found by
selecting “Start/Programs/SeaIO/Sample Application Description”. Information
about where the files are physically stored on your disk is also included in this same
file.

Programming for Linux

SeaI/O for Linux consists of two major parts: a kernel module

and a library. The

kernel module is a simple IO pass-through device, allowing the library to handle the
more sophisticated functions provided to SeaI/O users. It is provided in a ‘tarball’
format and can easily be compiled and included in the kernel build.

Digital I/O Interface

The DIO-32.PCIe provides four parallel input/output (I/O) ports. The ports are
organized as ports A, B, C, and D. Port A and B are input ports interfaced to
optically-isolated inputs, while ports C and D are reed relay output ports. Assuming
an I/O address of 300 Hex the following table shows the Port Addresses.

Base Address

Hex

Decimal

Mode

Port A Address

300

768

Optically Isolated Input Port

Port B Address

301

769

Port C Address

302

770

Reed Relay Output Port

Port D Address

303

771

© Sealevel Systems, Inc.