Card Setup

Sealevel Systems ULTRA COMM+I.LPCI Page

4

Clock Modes

The ULTRA COMM+I.LPCI employs a unique clocking option that allows the end user to select from divide by 4
and divide by 1 clocking modes. These modes are selected at switches SW-2.

To select the Baud rates commonly associated with COM: ports (i.e. 2400, 4800, 9600, 19.2, … 115.2K Bps) set
switch position 2 to the ‘On’ position (silk-screen D4). To select the maximum data rate (921.6K bps) set switch
position 1 to the ‘On’ position (silk-screen D1).

Caution: Do not set both switches in the ‘On’ position. This could potentially cause damage to the adapter,
and definitely cause a malfunction.

Figure 7 - Clocking Modes

D
1

D
4

A
T

R
T

1 2 3 4

ON

OFF

SW2

Divide by

1 mode

Divide by

4 mode

1 2 3 4

ON

OFF

D
1

D
4

A
T

R
T

SW2