AIP-00056 Rev. C – 08/06 Page 3/5

EARTH GROUND

LINE

1
2
3
4
5
6
7
8

LINE

58 VOLT

PROTECTION

DEVICE

1
2
3
4
5
6
7
8

AL-CAT6W Installation Instructions

1. Position the suppressor with the strain reliefs down
when mounting.

2. The data cable is connected to the suppressor
via the terminal strips.

Install the data cable through the strain reliefs, strip
back cable jackets as needed and terminate the data
wires to the screw down terminal blocks (Pinouts
located next to terminal strip).

Terminal strips can be removed to ease wiring.

CAT6 Pinout: 1 - Data 1 +

2 - Data 1 -

3 - Data 2 +

4 - Data 2 -

5 - Data 3 +

6 - Data 3 -

7 - Data 4 +

8 - Data 4 -

3. Adjust the cable inside the unit to ensure proper closing
of cover, then secure by tightening strain reliefs onto cables.

4. Attach cover using the provided hardware.

5. To ensure proper operation of suppressor,
install an earth ground to the external ground
lug on the unit.

Note: This unit provides Bi-Directional Protection,
input and output cables may be interchanged.

www.L-com.com

Copyright © This drawing is property of L-com Global Connectivity. All rights reserved.

L-COM, INC. 45 BEECHWOOD DRIVE NORTH ANDOVER, MA 01845

WWW.L-COM.COM E-MAIL: [email protected] PHONE: 1-800-343-1455 FAX: 1-978-689-9484

© L-com, Inc. All Rights Reserved. L-com Global Connectivity and the L-com logo are registered marks.