LEADER PHABRIX SDI ANALYSIS User Manual

Phabrix, Sdi analysis, Broadcast excellence

Advertising
background image

The SDI analysis option provides the engineer with a detailed

view of the data words contained within the SDI stream. This

allows the analysis of complex faults and is particularly useful

when determining compatibility issues between equipment and

when debugging new product developments within an R&D

environment. Detail within the active SDI stream can be viewed

with continuous update. Analysis can be obtained from the

generated or received SDI stream allowing quick comparison

checks.

A number of screen displays are provided for analysis.

GRID

With reference to pixels at the top of the screen and lines along

the left side of the screen, users can look within an x, y grid of

pixel and ancillary data. Samples can be viewed as 8 or 10 bit, hex

or decimal. Navigation is simple and fast using the thumb pad with

the selected value highlighted in white. A separate entry box

allows a specific line and sample to be selected. Both

the background and foreground text colours are coded for ease of

identification. The background colour at any time represents the

FVH bits within the TRS words. In this way the operator can

determine if a data element is active picture, vertical blanking,

horizontal blanking, field 1, field 2 or TRS. The foreground colour

gives an indication of the type of pixel data being viewed – Y, Cb,

Cr, R, G or B.

STREAM

This allows the SDI continuous stream to be viewed. SD-SDI

signals are represented by a 10 bit stream and HD/3G-SDI by a 20

bit stream. A further column provides information to aid the user in

identifying data types.

COMPONENT

The component view splits the display into 3 columns displaying Y,

Cb and Cr data as10/8 bit, hex or decimal.

SPLIT

This mode splits the SDI stream further into the components ‘Cb Y

Cr Y’ as 10/8 bit, binary, hex or decimal.

ANCILLARY DATA

This separate window allows the user to capture whole Ancillary

data packets identified by their data id (DID). Entering a known

DID value or by selecting its descriptive text, the Ancillary packet

will be continuously displayed if present within the SDI signal. Data

values containing errors found will be displayed in red text. The

data may be frozen on screen once captured. There is also a

freeze on error check box.

ORDERING INFORMATION

Option code

PHSXOSD

broadcast excellence

PHABRIX®

®

DETAILED DATA WORDS IN SDI STREAM

CONTINUOUS UPDATE

• SELECTABLE VIEWS, GRID, STREAM

COMPONENT, SPLIT

DATA ID (DID) ANCILLARY PACKET VIEW

SUPERIOR EASE OF USE

APPLICATIONS

R&D/TEST DEPARTMENTS

SYSTEM INTEGRATORS

SUPPORT ENGINEERS

AVAILABLE FOR

PHABRIX® SxA

PHABRIX® SxD

PHABRIX® SxE

FEATURE HIGHLIGHTS

SDI ANALYSIS

Grid view of the SDI stream showing coloured window sections and

highlighted value selected

Revision

02/14

Specifications and features described herein are subject to change without prior notice.
Please consult our website www.phabrix.com for the latest data.
PHABRIX is a registered trademark.

Represented in the Americas by

PHABRIX® TAG

(Requires PHSXT-GEN and PHSXOSD)

LEADER INSTRUMENTS CORPORATION

Fullerton, CA 92831

1501 E. Orangethorpe Avenue, Suite 140

Toll Free 1-800-645-5104

[email protected]

Tel 1-714-527-9300

www.LeaderAmerica.com

Advertising