Initial startup – Lectrosonics VR Field (Wideband) User Manual

Page 10

Advertising
background image

VR Field Wideband Receiver

LECTROSONICS, INC.

10

Initial Startup

When the Venue receiver is first powered up the LCD

will show the firmware revision and the tuning range of

the host assembly. The wideband version of the VRM

covers the entire 230 MHz bandwidth of frequency

blocks 21 through 29.

As the boot sequence continues, the display will switch

to an overview of all six receiver channels. In this ex-

ample, six receiver modules are installed but no trans-

mitters are turned on. In this case the “P” will be blinking

since no pilot tone is detected.

The wideband Venue receiver is different than the 50

MHz version in that the receiver modules are detected

through a manual process rather than automatically at

boot up. Press the MENU/SELECT control and rotate it

to select “Detect” on the menu.

Press the MENU/SELECT control to launch the detec-

tion process.

It takes about 45 seconds to detect all the modules and

update the memory in the host assembly. Once com-

pleted, the LCD will briefly display the results showing

the frequencies of the installed modules.

If a slot is not occupied by a module, the display will

place an “X” in that position.

The display then switches to the overview of all six

channels.

Any slot that is not occupied by a module will leave a

blank space in the overview display.

If a module in any position has been removed, changed

or added since the last use, the LCD will flash a mes-

sage advising that the Detect process needs to be run

again.

In normal operation with all six channels running, the

overview display will include:

• Audio level

• RF level

• Diversity antenna phase activity

• Pilot tone status

• Transmitter battery status

Audio level

RF level

Transmitter

battery status

Pilot tone status

Diversity activity

(in Switched mode)

Once the initial startup is complete, go to the next

section of this manual for details on setup and

configuration options.

To power off the unit, press and hold the red power

switch for several seconds. The LCD will display a mes-

sage briefly then power down.