Operating instructions, Cp 400, Power up and boot sequence – Lectrosonics SM User Manual

Page 9: Power down, Standby mode, Selecting the compatibility mode

Advertising
background image

Super-Minature Belt Pack Transmitter

Operating Instructions

Power Up and Boot Sequence

1) Ensure that a good battery is installed in the unit.

(See Battery Installation.)

2) Simultaneously press and hold the AUDIO and

FREQ buttons until the Power On Boot Sequence is

initiated. (See Power On Timer.) As the unit turns

on, the Modulation LEDs and PWR LED all glow

red, then green, and then they revert to normal op­

eration, i.e., the Modulation LEDs glow according to

the audio level present at the Audio Input Jack and

the PWR LED glows green (with a good battery).
The LCD displays a bootup sequence which con­

sists of four screens:
Company Name:
Frequency Block (bXX) and

Firmware Version (rX.X):
Compatibility Mode:
Audio:

Lectro

b21r1.5 (typ)
CP 400 (typ)
Aud 12 (typ)

Modulation

LEDs

LCD

Control Panel

PWR LED

UP Arrow

AUDIO Button

FREQ Button

Power Down

1) Simultaneously press and

OFF. . .3

hold the AUDIO and FREQ

Initial Power Off Timer

buttons while observing that

Screen

the word “Off” appears in

the LCD along with a counter.

2) When the counter reaches “0”, the unit turns off.

Note: If the AUDIO and FREQ buttons are

released before the LCD goes blank at the end of

the countdown, the unit will not turn off. Instead, it

will stay energized and the display will return to the

previous screen.

Standby Mode

Standby Mode allows the user to verify or change the

transmitter’s operating frequency or audio input level,

and lock or unlock the front panel controls without trans­

mitting any signals. Standby Mode can only be invoked

from a power off condition.

Quickly press and release both the AUDIO and FREQ

buttons simultaneously to enter and exit this mode.

Selecting the Compatibility Mode

All Digital Hybrid Wireless™ receivers are capable of

working with the Lectrosonics SM transmitter. By select­

ing the proper compatibility mode, the SM will also work

with 200 Series, 100 Series and IFB analog receivers,

plus some other analog wireless receivers (contact the

factory for details). Setting the Compatibility Mode of

the transmitter to match the receiver is easily done via

the Control Panel.

Note: RF transmission is prevented while selecting

Compatibility Modes. Also, the SM exits the

Compatibility Mode screen to Standby Mode. (See

Standby Mode, this section.)
Note: The unit comes from the factory configured

as a 400 Series transmitter.

1) Set the receiver’s audio controls to minimum.
2) Power up the SM and observe the Boot Sequence.

If the Compatibility Mode for the SM does not match

the corresponding receiver, then power off the SM

transmitter.

3) From a power off condition, hold down the Up

arrow, then simultaneously press the AUDIO and

FREQ buttons.

4) The LCD will display the current Compatibility

Mode. Use the Up or Down arrow buttons to reset

the Compatibility Mode to match the corresponding

receiver.
The following Compatibility Modes are available:

• 100 Series mode:

CP 100

• 200 Series mode:

CP 200

• Mode 3 (Contact dealer for

CP 400

details):

400 Series or Digital

CP 3

Hybrid Wireless™

• 400 Series mode:

Compatibility Mode

CP 400

• IFB Series mode:

CP IFB

• Mode 6 (Contact dealer for details): CP 6

5) The Compatibility Mode selected in Step 4 will be

the current Compatibility Mode until reset using this

procedure. Pressing the AUDIO or FREQ exits into

Standby Mode. To power off from the compatibility

mode screen, press AUDIO and FREQ together.

Rio Rancho, NM