Technical specifications

Protocol support

Wireless networks

• TDM
• ATM
• IP

SGW

• M3UA/SIGTRAN
• MTP3 NB
• MTP3 BB

Network attachment compliance

• ITU-T G.703
• ITU-T G.707
• ITU-T G.813
• ITU-T G.823
• ITU-T G.825
• ITU-T G.957

Voice CODECs

• G.711
• G.729ab
• EFR
• GSM HR
• GSM FR
• GSM EFR
• GSM AMR HR
• GSM AMR FR
• AMR
• AMR2
• AMR2 WB

Physical specifications

Chassis dimensions

• Height: 62.2 cm (24.5 in.)
• Width: 45.2 cm (17.4 in.)
• Depth: 47.3 cm (18.6 in.)

Rack dimensions

• Height: 200 cm (78.7 in.)
• Width: 60 cm (23.6 in.)
• Depth: 80 cm (31.5 in.)

Power

• Input voltage -40V DC to -60V DC
• Input current 65 A, dual feeds
• Power consumption: 3000 W

Operating temperature

• 5°C to 40°C (41°F to 104°F)

Regulatory compliance

Electromagnetic
compatibility (EMC)

• EN 300 386: Telecommunica-

tion Network Equipment,

EMC requirements

• EC 61000-4: Testing and

measurement techniques

• IEC 61000-4-2: Electrostatic

discharge

• IEC 61000-4-3: Radiated, radio

frequency, electromagnetic field

• IEC 61000-4-4: Electrical fast

transient/burst

• IEC 61000-4-5: Surge immunity
• IEC 61000-4-6: Immunity to

conducted disturbances, induced

by radio-frequency fields

• Telcordia GR-1089-CORE Iss 4,

Sections 2, 3, 4, 5, 6, 10

Safety

• UL 60950-1, 1st ed.: Safety of

information technology equipment

• CSA 22.2 60950-1-03 1st. ed.:

Safety of information technology

equipment

• CB Scheme/IEC 60950-1 1st ed.:

Safety of information technology

equipment

Power and grounding
requirements

• Telcordia GR-1089-CORE, Section

9 Bonding and Grounding

Climatic and mechanical

• ETS 300 019-2-1: Environmental

conditions and environmental

tests for telecommunications

equipment – Part 21: Specifica-

tion of environmental tests:

storage

• ETS 300 019-2-2: Environmental

conditions and environmental

tests for telecommunications

equipment – Part 22: Specifica-

tion of environmental tests:

transportation

• ETS 300 019-2-3: Environmental

conditions and environmental

tests for telecommunications

equipment – Part 23: Specifica-

tion of environmental tests:

stationary use at weather-

protected locations

• Telcordia GR-63-CORE Iss 3,

Sections 2, 4.1.1, 4.1.2, 4.1.3,

4.1.6

Fire resistance

• Telcordia GR-63-CORE, Sections

4.2 and 5.2

Seismic

• ETS 300 019-2-3/A1
• Telcordia GR-63-CORE Iss 3,

Section 4.4.1

Acoustics

• ETS 300 753 Class 3.1 (1997):

Acoustic noise emitted by tele-

communications equipment

• Telcordia GR-63-CORE Iss 3,

Section 4.6

www.alcatel-lucent.com

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo

are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility
for inaccuracies contained herein. Copyright © 2008 Alcatel-Lucent. All rights reserved.
CAR9718081120 (12)

Advertising