DMPA12 Installation Guide

Rio Rancho, NM

9

Programmable Inputs and Outputs Wiring

Remote control with external pots and switches is provided with Programmable Inputs on a standard DB-25 connector

on the rear panel. Programmable Outputs are used to provide external LED indicators and to trigger other events.
Examples of the wiring are shown below.

PROGRAMMABLE INPUTS/OUTPUTS

1 - GND

2 - IN 1

3 - IN 3

4 - IN 5

5 - IN 7

6 - IN 9

7 - IN 11

8 - GND

9 - OUT 1

10 - OUT 3

11- OUT 5

12 - OUT 7

13 - GND

14 - +5V

15 - IN 2

16 - IN 4

17 - IN 6

18 - IN 8

19 - IN 10

20 - +5V

21 - OUT 2

22 - OUT 4

23 - OUT 6

24 - OUT 8

25 +5V

1

13

ccw

cw

ccw

cw

ON

OFF

OUT 3

OUT 4

OUT 1

IN 1

IN 2

IN 3

500 Ohms

500 Ohms

500 Ohms

LED

LED

LED

Potentiometer

Potentiometer

Switch

Three Programmable Inputs:

2 - 10 K linear potentiometers

for volume control

1 - Tobble switch for muting

3 Programmable Outputs:

LEDS for function indicators

(380 to 500 Ohm resistors in-line

to avoid burning out LEDS)

NOTE

Common Connections can be used for

all voltage and ground connections

among all devices.