Liquid Controls LCRII E3651-E3656 Wiring Schematic User Manual

S1&2, Two stage, Single stage

Advertising
background image

LECTROCOUNT LCR-II CPU 840404 WIRING SCHEMATIC

OPTICAL AIR AND

VAPOR ELIMINATORS

81947

Optical Sensor

502011

S3 Solenoid Valve

Gnd/Black (54)

In5/White (55)

+VP/Red (52)

Out8/Black (53)

+VP/Red (56)

Out8/Black (53)

+VP/Red (52)

2

1

S3

J15

Terminal

TEMPERA

TURE PROBE

White (20)

White (21)

Red (22)

Red (23)

J14

Terminal

ETVC

(Electronic Temperature Volume Compensation)

71130 Temperature Probe

J8

Terminal

11

12

13

PRINTER

SERIAL 485

TERMINAL

POWER

COUNTER

MH1

CTS RXD TXD RTS

GND

GND

485+A

485-B

CTS RXD TXD RTS +VP

EARTH

GND

GND

IN 1

IN 2

IN 3

IN 4

+5V OUT

+VP

GND

+12-24V

MH4

J20

J6

J3

J2

J1

J7

J7

C2

24

25

+5V(Out)/Jumper

(59 to 32)

B

DIFFERENTIAL

PRESSURE (∆P)

TRANSDUCER

J1

Terminal

J3

Terminal

82637

∆P Transducer Kit

81944

DP/Printer

Board

Auxiliary Output 1 (Out 1)

Auxiliary Output 2 (Out 2)

Pulse Output (Out 3)

J12

Terminal

AUXILIARY OUTPUTS

AUXILIARY DEVICE

i.e Dead-Man

Shutdown

Auxiliary

Device

J13

Terminal

Out7

+Vo

Power, input and output (I/O) wiring must be in accordance

with the area classification for which it is used (Class I, Div 1).

For North America, installations must be per the U. S. National

Electrical Code, NFPA 70, or the Canadian Electrical Code

in order to maintain Class I, Division 1 ratings. This may

require using connections or other adaptations in accordance

with the requirements of the authority having jurisdiction.

WARNING: Explosion Hazard - Substitution of components

may impair suitability for Class I, Division 1 applications.

WARNING: Explosion Hazard -

When in hazardous locations,

turn power OFF before replacing

or wiring modules.

WARNING: Explosion Hazard -

Do NOT disconnect equipment

unless power has been switched

OFF or the area is known to be

Non-Hazardous.

For positive ground installation,

contact the Liquid Controls Service Department

GND/

Blac

k (41)

DN/

Green

(40)

+V

o/

Re

d (45)

UP/

White

(39)

LECTROCOUNT

REMOTE DISPLAY

J12

Terminal

81816

Remote Display Cable

INTERNAL

PULSER

(or POD 5)

DMS i1000

J1

Terminal

J2

Terminal

J3

Terminal

81513040

Black Data

Cable 40’

Violet and red

wires move from

48 & 46 to

25 & 24

+VP

/R

ed
(24)

TXD/

Violet

(25)

RXD/

Gr

ay

(49)

CTS/

Green

(50)

GND/

White

(51)

GND/

Blac
k

(30)

CTS/

Blue

(29)

RXD/

Yello
w

(28)

TXD/

Or

ang
e

(27)

RTS/
Br

own
(26)

24

25

SERIAL J2

TERMINAL J3

PRINTER J1

J3 Terminal

can be

disconnected

PRINTER

+VP/Red (46)

TXD/Violet (48)

RXD/Gray (49)

CTS/Green (50)

GND/White (51)

GND/Black (30)

CTS/Blue (29)

RXD/Yellow (28)

TXD/Orange (27)

RTS/Brown (26)

J1

Terminal

J3

Terminal

81513040

Black Data

Cable 40’

81514

Lap Pad Adapter
E40301

Lap Pad

TERMINAL J3

PRINTER J1

24

25

825001

Printer Power Cable

81838

Membrane Switch

81839

Membrane Switch Harness

J8

Terminal

Blac

k (38)

Violet

(36)

Gre

y

(35)

MEMBRANE

SWITCH

81915 LCR-II LCD Display

81832

LCR-II Switch Harness

81819

LCR-II Switch Plate

81330

LCR-II Display

Coiled Cable

J6

52

5354

55

56

PRINTER

SERIAL 485

TERMINAL

POWER

COUNTER

MH1

CTS RXD TXD RTS

GND

GND

485+A

485-B

CTS RXD TXD RTS +VP

EARTH

AUX OUTPUTS

PULSE INPUTS

AUX I/O

GND

GND

GND

IN 1

OUT1

OUT2

OUT3

TEMPERATURE PROBE

ASSY

84040 REV.

RTD+S

RTD-D1

RTE-S

RTD+D

OUT4

OUT5

IN 2

IN 3

IN 4

+5V OUT

+VP

+VP

PGND

OUT6 +VP

SOL

+VP

PGNDOUT7

+VF

+VF

IN5

OUT8

GND

GND

+12-24V

MH4

C1

J20

J3

J2

J1

J7

J12

J15

P1

TP1

J5

J14

J18

J19

J10

J17

J11

J7

C2

MH5

MH3

MH2

A

B

24

25

11

12

13

J1

Terminal

J2

Terminal

J3

Terminal

J6

Terminal

J8

Terminal

J12

Terminal

J15

Terminal

J13

Terminal

J14

Terminal

CPU

84040

J10 Communications Jumper

LCR-II - In A position for Lap Pad

all other functions in B position

POWER

EARTH/Shield (13)

GND/

Blac
k

(12)

11

12

13

+12-24/Red (11)

Open

Drain

Battery or

Accessory Panel

GROUND

DC

Power

Supply

Power

Supply

81512

40' Gray

Power

Cable

7.5A

In-Line

Fuse

E3655/E3656

SOLENOID

VALVES

J13

Terminal

Jumper from

Terminal 15

to Terminal 18

Earth/Green (16)

Out7/Black (15)

+12V/Black (14)

S1&2

J13

Terminal

Earth/Green (16)

Earth/Green (19)

Out7/Black (15)

Out6/Black (18)

+12V/Black (14)

+12V/Black (17)

Earth/Green (19)

Out6/Black (18)

+12V/Black (17)

2

1

Earth/Green (16)

Out7/Black (15)

+12V/Black (14)

2

1

Two Stage

81527 3-Way Solenoid (LPG)

A2859-11 Block Valve (LPG)

A2848-11 Two Stage Block Valve

A2982 E-7 Two Stage Piston Valve

Single Stage

81527 3-Way Solenoid (LPG)

A2843 Block Valve (LPG)

A2847-11

Single Stage Block Valve

Solenoid operated valve 81527

(3-way LPG solenoid) has 3 cables

potted into the housing. All other

solenoid operated valves on Liquid

Controls valves use cable assembly

81859, which has 2 cables.

The Earth grounds for Terminals 16

& 19 are optional. The solenoid

operated valves are grounded

through the component they are

mounted on.

ESD PRECAUTION

OPENING LECTROCOUNT REGISTERS

Before opening the LectroCount register

and handling the CPU board, it is important

to discharge any ESD that may have built up

on your person. To discharge ESD from your

person, touch a well-grounded point such as

the LectroCount register housing, the meter,

the truck piping, or the bumper. When the

maintenance is complete and the LectroCount

register door is closed, the CPU board is

protected from ESD by the LectroCount

register housing which is grounded

to the chassis.

SOL

J13

SOL

J13

SOL

J13

AUX I/O

J15

AUX OUTPUTS

J12

AUX OUTPUTS

J12

POWER

J6

PULSE OUTPUTS

J8

A/Blue (58)
+5V/
Red (59)

B/Yellow (57)

GND/White (51)

+VP/Black (46)

PULSE OUTPUT

DEVICE (POD) 1-4

GND

/Blac

k

(37)

CHB/

Green

(34)

CHA/

White

(33)

+V

o/

Re

d (31)

J8

Terminal

PULSE OUTPUTS

J8

GND/

Blac

k (37)

CHB/

Green

(34)

CHA/

White

(33)

+5/

Re

d (32)

J8

Terminal

82597

Internal Pulser Kit

PULSE OUTPUTS

J8