Introduction - lcr 600 instruments and controls, Red selector switch – Liquid Controls LCR 600 Setup & Op User Manual

Page 6

Advertising
background image

6

IntroductIon - lcr 600 InStrumentS and controlS

red Selector Switch

The LCR 600 red selector switch, located at the bottom left of the LectroCount LCR 600, has five positions. The

selector switch’s primary purpose is to control everyday delivery and print functions. Functions include opening and
closing the control valve in order to start and stop deliveries and prompting the printer to print delivery tickets and shift
tickets.

the fIve poSItIonS on the Selector SWItch

Run - opens the control valve to begin a delivery

Stop - closes the control valve to pause a delivery

pRint - ends a delivery and prints a delivery ticket

Shift pRint - ends a shift, prints a shift ticket, and resets

shift data in the LCR 600

Calibration position - allows access to calibration

configuration settings.

Red Selector Switch

Six O’clock Calibration Position

calIbratIon poSItIon

The red selector switch also provides a secure
calibration position. When in the calibration position, the
LCR 600 may be used to calibrate the meter and enter
sensitive Weights & Measures data.

To turn the selector switch into the six o’clock calibration
position, the LCR 600’s switchplate must be removed. To
take off the switchplate, remove the four screws holding
it in place. If the LCR 600 has been previously calibrated
and approved by Weights & Measures, you will need to
remove the lead seal and the wire threaded through the
switchplate screws.

Selector Switch & Seal

LCR 600

LCR 600 without Switchplate