lCP seTuP ConfIguraTIon

retries:

After an initial failed attempt, the number of attempts the computer

will try to make a connection with the wireless communication network

before timing out. (1 is the default value)

Timeout (ms):

The amount of time the computer will wait for a response once a signal

is sent to a wireless network, before timing out. (2000 is the default

value).

IP Config:

Clicking the button activates IP Configuration settings.

Serial Config:

Clicking the button activates Serial Configuration settings.

local IP Port:

A port where TCP/IP communication can be heard. To get around

existing firewalls, your office PC will need to be configured so that TCP

data is accepted at this port number.

lCP setup

LCP Setup sets up the communication link at your PC or server in the office, configuring the office computer

for wireless communication. LCP Setup contains settings for IP configurations (Wifi and cellular) and serial

configurations (radio and direct serial cable). For successful data transmission, the settings in LCP Setup must be

configured to match the communication settings of the DMSs, LCR 600s, and wireless transmission devices in the LC

fueling network. LCP Setup includes a Test tab, where connection between the computer and a specific DMS or LCR

600 (or another computer) can be tested.

LCP Setup - Configuration

Value must match value in the cell modem’s internal setting

(see cell modem manual for setting its IP port). Liquid Controls

recommends 7050 for the value. It is not a common IP Port number

used by other programs such as ftp and email applications.

network node:

The LCP network node number of the device the computer is communicating with. 1-255 range

network IP address:

The IP address of the device the computer is communicating with, using TCP/IP protocol

network IP Port:

The IP port number of the device the computer is communicating with, using TCP/IP protocol

Port name:

The computer’s serial communication port the data communication device is connected to.

TX enable:

The setting for the serial signal transmit and receive handshake technique to the data communication device. None is the default setting.

None • !RTS • RTS • !DTR • DTR • !RTS!DTR • RTSDTR

baud:

The communication speed. This value should match the wireless device. 57600 is the standard communication speed, but check your

wireless device specifications to ensure the proper selection.

115200 • 57600 • 19200 • 9600 • 4800 • 2400

Cancel

Closes the window without saving.

save

Saves settings that appear in the window.

done

Saves settings that appear in the window and closes the window.

lCP seTuP

- seTuP

Advertising