Water connection, Permissible water pressure – AEG LAVAMAT 60300 User Manual

Page 40

Advertising
background image

Installation and Connection Instructions

40

Water connection

3

The washing machine is provided with safety devices which prevent
reverse pollution of drinking water and conform to the State regula-
tions issued by water supply authorities (e.g. in Germany: DVGW Direc-
tives). Further protective measures in the installation are hence
unnecessary.
Attention! Appliances for cold water connection may not be con-
nected to warm water!

Permissible water pressure

Water pressure must be equal to a least 1 bar (= 10N/cm

2

= 0.1 MPa),

and no more than 10 bar (= 100N/cm

2

= 1 MPa).

• By more than 10 bar: connect a pressure reduction valve upstream.

• By less than 1 bar: Unscrew the flexible inlet tubing on the magnetic

inlet valve on one side of the appliance and remove the flow meter
(thereby remove the sieve by means of a pair of pointed pliers and
then remove the rubber washer behind it). Remount the sieve.

Advertising