Model e1618 - wiring, Wiring model e1618 (lcmag™) – Liquid Controls XL LED Display E1615_E1616_E1617_E1618 User Manual

Page 11

Advertising
background image

wiring model E1618 (LCmag™)

Model E1618 of the LectroCount XL LED Remote Display will accept the calibrated pulse output of the LCMag

HML210 converter.
Since the HML210 does not have an output signal to reset the LED Remote Display, a Reset Switch Kit (PN 82592) is

required for this application. The Reset Switch Kit resets the XL LED Remote Display to zero between deliveries.

to wire the LectroCount XL LED Remote Display model E1618 to the hmL210 Converter:

1. Install Reset Switch Kit. page 16
2. Open the LCMag HML210 converter. Refer to manual IEM200-10 for specific

instructions regarding opening, closing, and sealing the converter.

3. Route the shielded cable through a cable gland and into the HML210

housing.

4. Connect the display’s shielded cable wire to the designated terminals on

the HML210 CPU board

• XL LED terminal 53 (red wire) to HML210 terminal 15

• XL LED terminal 54 (white wire) to

HML210 terminal 16

• XL LED terminal 56 (black wire) to

HML210 terminal 17

5. Tighten the cable gland and close the HML210 converter.

moDEL E1618 - wIRInG

A jumper is required between terminal 52 and terminal 53 on the display’s J1 terminal block. Display

units from the factory will include the jumper. When rewiring, ensure that this jumper is in place.

J1 Jumper - LectroCount XL LED Remote Display

LCMag™ PCB

11 12 13 14 15 16 17 18 19 20

Remote Display

PCB Board

GND

/Blac

k (56)

GND

/Blac

k (17)

B/White

(54)

PWR

/R

ed

(53)

B/White

(16)

PWR

/R

ed

(15)

Jumper

Reset Switch

RES

COM

11

12

13

J2

Shieled cable

ground wire

grounded to

remote display

PCB board

The LectroCount XL LED Remote Display

is supplied with a 30 foot 4-wire shielded

cable with 22 gauge wire. If alternate

cabling is required, Liquid Controls

recommends a similar 4-wire shielded

cable with 22 gauge wire or larger and a

maximum cable length of 30 feet.

Shielded Cable

If the power to the HML210

exceeds 24 VDC, then the remote

display should be powered from

Pin 32 on J8, 5 VDC.

24 VDC Power

11