What LC Strainers Do

Strainers protect meters from serious damage caused
by burrs dislodged from new piping, pipe scale, or foreign
material.

The strainer’s initial cost is good insurance against the
cost of down time or replacement parts incurred from a
damaged meter.

A meter strainer installed on the inlet side is necessary
even when a coarse strainer on the upstream side of the
pump is included in the system.

Strainers are not meant to be used as a system filter but
as protection for the meter element itself.

How LC Strainers Work

As liquid product enters the strainer housing from the
supply line, it is routed through the strainer basket. The
strainer basket is a two-ply screen. The inner screen is
made of fine mesh of either 20, 40, 80, 100, or 200
squares per inch. The outer screen works as a backing.
It gives reinforcement and support to the fine mesh inner
screen.

Liquid product is filtered and exits the strainer basket
through the screens into the strainer housing. The liquid
then passes through the outlet of the strainer and into
the inlet of the meter. Any debris larger than the mesh in
the basket is trapped.

A properly maintained strainer helps to ensure the system
owner years of trouble free service.

Features

LC markets a wide variety of strainers to fit most meters
in terms of capacity, pipe size, working pressure and
metallurgical compatibility. The design advantages of a
Liquid Controls strainer include:

Strainer baskets with an unusually high open basket
area to pipe area ratio, resulting in minimum
restriction of flow and low pressure loss.

A choice of stainless steel strainer basket mesh sizes.
Part Number

Description

A3430 ............. 40 Mesh
A3431 ............. 80 Mesh
A3432 ............. 100 Mesh
A3433 ............. 20 Mesh
A3434 ............. 200 Mesh

2" High Capacity Strainer .................................... 6-7

Dimensional View ................................... 6
Exploded View ........................................ 7

3" High Capacity Strainer .................................... 8-9

Dimensional View ................................... 8
Exploded View ........................................ 9

Troubleshooting................................................... 10-11

Description

Page Number

Publication Updates and Translations

The most current English versions of all Liquid Controls publications are available on our website, www.lcmeter.com.
It is the responsibility of the Local Distributor to provide the most current version of LC Manuals, Instructions, and
Specification Sheets in the required language of the country, or the language of the end user to which the products are
shipping . If there are questions about the language of any LC Manuals, Instructions, or Specification Sheets, please
contact your Local Distributor.

!

!

!

!

!

WARNING

WARNING

WARNING

WARNING

WARNING

Before using this product, read and understand the instructions.

Save these instructions for future reference.

All work must be performed by qualified personnel trained in the proper application, installation, and
maintenance of equipment and/or systems in accordance with all applicable codes and ordinances.

Failure to follow the instructions set forth in this publication could result in property damage, personal injury,
or death from fire and/or explosion, or other hazards that may be associated with this type of equipment.

Advertising