E-7 Electronic Two-Stage Preset Valve

The Liquid Controls E-7 Electronic, Two-Stage, Preset Valve is designed for
refined fuel applications including gasoline, gasohol, diesel fuel, and fuel
oil. The valve is available as part of a complete, new metering system with
electronic registration or as a retrofit when upgrading from mechanical to
electronic registration. The E-7 valve may be used with M5, M7, and M10
Class 1 meters.

Features of the E-7 Valve include:

Indexible design for 90° rotational adjustment of valve outlet.

Interchangeability (same mounting dimensions) with the V-7 and K-7
mechanical valves.

Two-stage operation for preset deliveries.

Fast response for quick valve shut-off.

The E-7 Series electronically-actuated piston valve is mounted on the
meter outlet and provides a compact installation. The valve is operated by
two solenoids. These solenoids control two-stage closure with a dwell
period to eliminate hydraulic shock.

The valve solenoids are wired to a Liquid Controls LectroCount Electronic Register and are controlled by the
register software. During a delivery, the valve opens to allow full flow through the meter. For preset
deliveries, the full flow solenoid de-energizes at the point where dwell flow is activated. This reduces the
flow rate through the meter. Once the delivery preset volume is reached, the valve fully closes without
hydraulic shock to the system.

Environmental Rating
NEMA 4X

Safety
Designed to meet Class I, Division 2
requirements

Materials of Construction
Valve Body:
Aluminum
Elastomers: Viton O-Rings, Teflon Seal, Acetal
Wear Rings

Pilot Control System
Solenoids, Tubing and Fittings:
Brass
solenoids and fittings with flared copper tubing

Temperature Rating
-40° to 160°F (-40° to 71°C)

Pressure Rating
Maximum non-shock working pressure
• 150 PSI (10.3 BAR)
Maximum differential pressure
• 100 PSI (6.9 BAR)

Maximum Nominal Flow
150 GPM (568 L/min) for 30 SSU products

Viscosity Range
30 to 100 SSU

Products
Class 1:
refined fuels (gasoline, gasohol,
diesel fuel, and fuel oil)

Solenoids
Voltage:
+10.2 to 13.6 VDC
(Optional Voltage: +20.4 to 27.2 VDC)
Current: S1: 1 Amp, S2: 2 Amps maximum

Technical Specifications

Specifications

www.lcmeter.com