Sponsler, Inc.

SP717 Modulated Carrier Amplifier

pg 3

DOC#” MN-717-A

BENCH TEST CALIBRATION PROCEDURE

Required Equipment: Power Supply 6-28 VDC, Frequency Generator, Frequency Counter,

Oscilloscope

Test Procedure:

A) Connect RF pickup coil to J1-1,2

B) Connect power supply positive & negative leads to J1-3,5 respectively

C) Connect oscilloscope positive & negative leads to J1-1,2 respectively

D) Install jumper @ JU1

E) Turn power supply “ON”, observe LED D1 illuminates and oscilloscope

displays a 50khz + 5Khz carrier sinewave

F) Observe carrier amplitude of 6Vp-p nominal

G) Connect oscilloscope positive & negative leads to J1-4,5 respectively

H) Connect frequency generator positive & negative leads to J1-1,2 respectively.

Set function to squarewave, amplitude to 5Vp-p & frequency to 1-3500 Hz.

I) LED D2 illuminates & the oscilloscope displays a squarewave whose

frequency is that of step H with a positive amplitude .6V < power supply

positive potential and a negative amplitude .6V > power supply negative

potential.

J) Observing oscilloscope display momentarily short pins J1-4 & 5 together. The

oscilloscope will display a squarewave with an amplitude of .6V or less.

When the short is removed the oscilloscope will display a normal amplitude

squarewave.