STEP
9
SETTING
RELAY
FUNCTION
AND
ON TIMES
PRESS
DISPLAY
MENU FLASHES TO DEV TYP
LOCKOUT
OUTCARD
ALG OUT
OUT FREQ
RELAY
(RELAY SELECTED)
A GR TOTAL
(RELAY A SET TO GRAND TOTAL)
A RATE
(IF RATE SELECTED, DURATION
IS DISABLED)
A TOTAL
(RELAY A SET TO TOTAL)
(PRESS AS DESIRED)
DUR A #.#
DUR A 0.0
(AS AN EXAMPLE)
DUR A 1.2 (RELAY ACTIVATES FOR 1.2 SEC.)
(ON TIME ENTERED)
B RATE
(IF RATE SELECTED, DURATION
IS DISABLED)
B TOTAL
(RELAY B SET TO TOTAL)
B GR TOTAL
(RELAY B SET TO GRAND TOTAL)
(PRESS AS DESIRED)
DUR B #.#
DUR B 0.0
(AS AN EXAMPLE)
DUR B 5.5 (RELAY ACTIVATES FOR 5.5 SEC.)
(ON TIME ENTERED)
LAST COUNT READING
R ###### (RATE READING)
######## (BATCH TOTAL)
PRESS C TO GO BACK TO RATE AGAIN
GR TOTAL FLASHES THEN THE GRAND TOTAL
VALUE FLASHES
######## (BATCH TOTAL)
PRESS C TO GO BACK TO RATE AGAIN
PRESS ENT TO GO BACK TO GRAND TOTAL
D
D
D
D
D
D
ENT
D
D
ENT
CLR
1
2
ENT
D
D
ENT
5
5
ENT
CLR
C
C
ENT
ENT
VIEWING
RATE,
BATCH
TOTAL,
GRAND
TOTAL
7