Liquid Controls SP3850 User Manual

Page 60

Advertising
background image

SP3850 Flow Computer

56

Sub-menus

Display

Notes

Pulse out test

Pulse out test
*0Hz 1Hz 10Hz 20Hz

Pulse out test

Relay Test

Rly1 Rly2 Rly3 Rly4
Off Off Off Off

Relay Test

Control inputs test

TB1-9 TB1-10 TB1-11
Off Off Off

Control inputs test

8.2.21
Pulse out test
Submenu Group

ENTER

MENU

Press Enter key to test the pulse output.

To simulate a frequency on the pulse output:
Connect a frequency counter to (+)TB1-13,
(-)TB1-14. Press the key under the desired
setting to move the asterisk (*). The unit
should output the selected frequency.

Press Menu key to return to Pulse out test
top-level menu.

Press Enter to test the relays.

To manually control the relay outputs: Press
the key under the desired relay to toggle the
relays On/Off. Use an ohmmeter to check the
relay contacts.

Press Menu key to return to Relay Test top-
level menu.

Press Enter to test the control inputs.

To check the control inputs: Use TB1-12 as
reference, input a positive 3-30 VDC signal to
TB1-9, TB1-10 and/or TB1-11, The Display
will show ON when input is active, OFF when
inactive.

Press Menu key to return to control input test
top-level menu.

ENTER

MENU

8.2.22
Relay test
Submenu Group

ENTER

MENU

8.2.23
Control input test
Submenu Group

Advertising