Lightronics FXLD89FRP4I User Manual

Lightronics Lighting

Advertising
background image


Page

1

of

6

FXLD89FRP4I LED FIXTURE

Version 0.1 OWNERS MANUAL 07/11/2013

www.lightronics.com

Lightronics

Inc.

509

Central

Drive

Virginia

Beach,

Va

234354

757

486

3588

FEATURES AND SPECIFICATIONS

LEDS: 9, 8 Watts each (R,G,B,W - 4 in 1)
Beam angle: 25 º
Control system: DMX-512 + Stand Alone Modes
DMX channels: 4/5/7
DMX connectors: 3 pin XLR
Voltage: 100 - 240 VAC 50/60Hz
Max power consumption: 90 Watts
Cooling: Internal Fan
Body material: Die Cast Aluminum
Body color: Black
Size: 11.2"L x 9.75"W x 4.7"H (without brackets)
Weight: 8.8 lbs (4kg)

DESCRIPTION

The FXLD89FRP4I is a RGBW LED lighting fixture.
It is suitable for stage, disco, night club, and other
artistic applications. It has several stand alone control
modes and can operate via a DMX-512 external signal.

A double yoke enables the fixture to be operated in
several positions.

INSTALLATION

LOCATION

The FXLD89FRP4I is rated IP20 and is intended for

INDOOR USE ONLY.

Locate the unit in a well ventilated area away from
moisture and heat. Keep the vent holes clear. Holes
are provided on the yokes to install a lighting bar pipe
clamp. Use a safety cable when hanging the fixture.

POWER CONNECTIONS




The FXLD89FRP4I has a male IEC style connector for
power input. A compatible power cable is provided for
connection to a 120 VAC, 15 Amp, 60Hz, service.

A female IEC style connector on the unit is used to
pass power on to another unit. A cable for this purpose
is also provided.

Caution is advised since the line cord is rated for
aprox. 7 Amps maximum.


























THE SAFETY GROUND TERMINAL ON ALL POWER
CABLES MUST BE USED.

DMX CONNECTIONS

A system using DMX control should be connected as a
chain of devices. In other words the control signal
cable should proceed from the controller to the first
receiving device and then to others in a continuous
"daisy chain" fashion.

The fixture has a DMX IN and a DMX OUT connector
to be used to connect the chain. The control cable
should NOT be split into a multiple run star
arrangement with a cable running from the controller
directly to each receiving device pack.

DMX CONNECTOR PIN ASSIGNMENTS

There are two different connectors which can be used
for DMX control. They are both XLR type connectors.
Some units use 3 pin connectors. Others use 5 pin
connectors. The FXLD89FRP4I receives a DMX
signal on the 3 pin MALE connector on one side of the
unit. The 3 pin FEMALE connector is used to connect
the next DMX device on the control chain.

CAUTION

RISK OF ELECTRIC SHOCK

Advertising