Lightronics FXELP10 (during-after May 2009) User Manual

Page 2

Advertising
background image

PROFILE SPOT575

OWNERS MANUAL

Page 2 of 4

Ellipsoidal

Lighting

Fixture

Version 20101007

POWER CONNECTIONS

DANGER

RISK

OF

ELECTRIC

SHOCK

The

fixture

must

be

correctly

grounded

and

must

be

installed

to

comply

with

all

applicable

regulations.

The unit is supplied with a power cable and may be
provided with a power cable connector. The two wires
with WHITE SLEEVING are for the HOT (Power) and
the NEUTRAL.

The GREEN / YELLOW conductor in the power cable
is connected to the fixture case as a safety ground.
This conductor must be used if installing a alternate
cable connector.


LAMP REMOVAL / INSTALLATION

The Profile Spot 575 fixture uses a OSRAM GLA/575
or GLE/750 (G9.5 Base) lamp

Before installing a lamp verify that the lamp is
compatible with the voltage at your facility. Operating
lamps beyond their rated voltage reduces lamp life and
can cause other lamp failures.

Disconnect all power from the fixture.

Allow the fixture to cool off before proceeding.

Do not touch the lamp glass envelope with your
fingers

1. Unscrew the knurled screw on the lamp housing.

2. Remove the lamp housing from the fixture.

3. If replacing a lamp, remove the old lamp from the
socket.

4. Insert a lamp into the lamp socket.

5. Reinstall the lamp housing.

Do not operate the lamp unless the lamp housing
is installed in the fixture.

LAMP ADJUSTMENT

The lamp holder is aligned at the factory. Due to
differences between lamps, fine adjustment may
improve light performance.

Operate the fixture at full intensity. Open the shutters.
Focus the light on a flat surface such as a wall.


Center the hot-spot (the brightest part of the beam)
using the 3 adjustment screws A, B, C. Turn one
screw at a time to drag the hot-spot diagonally across
the projected image.

If you cannot detect a hot-spot, pull the lamp in by
turning all screws A, B, and C clockwise ¼ turn, one at
a time, until the light is evenly distributed.

If the light is brighter at the edges, or if light output is
low, the lamp is too far back in the reflector. Push the
lamp out by turning the screws A, B, and C ¼ turn
counterclockwise, one at a time, until the light is bright
and evenly distributed.


FOCUSING

1. Loosen the focus knob on the barrel.

2. Adjust the focus by sliding the lens tube forward
or

backward.

3. Tighten the focus knob.

OPERATION

CAUTION - HOT SURFACES

Do not touch any part if the fixture

during operation. It can operate at

temperatures

which

can

cause

severe

burns.

Do not operate the lamp unless the lamp holder is
installed in the fixture.

The lens and gel holder must be installed when the
fixture is operating.

Do not project the beam onto nearby flammable
surfaces. The minimum distance is 5 meters.

Once correctly installed, the fixture may be operated
by applying power via a dimmer or other compatible
power.

Switching the lamp on and off at short intervals will
reduce the life of both the lamp and the fixture.

CLEANING AND MAINTENANCE


DANGER
RISK OF ELECTRIC SHOCK

Disconnect

all

power

from

the

fixture

Before

proceeding.

Allow the fixture to cool off before proceeding.


Advertising