TX – 30 PROTOCOL TRANSLATOR

Revision 0.2

OWNERS MANUAL

03/02/2005

www.lightronics.com

Lightronics Inc

509 Central Drive Virginia Beach, VA 23454

Tel 757 486 3588


TX192 OPTION

The TX-30 may be optionally supplied to transmit the AMX-192 protocol. This model transmits both LMX and
AMX simultaneously. An external power supply is included and is needed with this option. The AMX-192 output
signal is transmitted from a 4 pin, male, XLR connector located at the rear of the unit.

CAUTION: Some AMX dimmer equipment uses a 4 pin MINI-DIN connector for the control signal. That
connector is NOT wired the same as the 4 pin XLR connector. The following table provides the information
needed to make an adapter cable.


AMX-192 CONNECTOR WIRING

Signal

Name

XLR

Connector

Pin #

MINI-DIN

Connector

Pin #

Common 1

2

Clock +

2

3

AMX Signal

3

4

Clock -

4

1










EXTERNAL POWER SUPPLY INFORMATION

Input Voltage:

120VAC

Output Voltage:

13.5 VAC

Output Current:

800 Milliamps

Connector:

2.1mm female connector


The TX-30 will operate using an alternative external power supply which can provide anywhere from 13 to 24
Volts AC or DC. The supply must be rated at 600 ma. If a DC supply is used, the center pin of the connector
MUST BE THE NEGATIVE output terminal of the supply.


MAINTENANCE AND REPAIR

TROUBLESHOOTING

Verify the cables (a very common source of problems!).

Ensure that all system units are powered - particularly the dimmer to which the translator is connected.

Check address settings at dimmers, console, and translator. Check console patch configuration.


REPAIR

There are no user servicable parts in the unit. Internal service by other than Lightronics authorized agents will
void the warranty. If service is required, contact the dealer from whom you purchased the unit or contact the
Lightronics Service Dept..