IDP-104 DMX OPTICAL ISOLATOR

Version 0.1 OWNERS MANUAL 07/13/2012

www.lightronics.com

20090526

drp

Lightronics

Inc.

509

Central

Drive

Virginia

Beach,

Va

234354

757

486

3588


INSTALLATION


Diagrams in this manual show all signal and power
connections for both the portable and wall mount units.


POWER SUPPLY


The IDP-104 will operate using any external power
supply which can provide 13 - 24 Volts AC or DC at
600 mA minimum. The size of the power input
connector on the unit is 2.1mm X 5.5mm. If an
external DC power supply is used, the center pin of the
connector MUST be the NEGATIVE side of the
supply.

The power supply normally provided with unit is
13VAC, 800 mA.


OPERATION


Operation is automatic when the power supply and a
DMX input signal are connected. The front panel
contains a power indicator LED which is lighted when
power is applied. A "DMX VALID" LED indicator is
lighted when a DMX input signal is present.

MAINTENANCE


There are no user servicable parts in the unit. Internal
service on the unit by other than Lightronics authorized
agents will void the warranty.

Dealer and Lightronics factory personnel can help you
with operation or maintenance problems. Please read
the applicable parts of this manual before calling for
assistance.

If service is required - contact the dealer from whom
you purchased the unit or contact Lightronics, Service
Dept., 509 Central Drive, Virginia Beach, VA
23454 TEL: (757) 486-3588.