Magnum Venus Plastech PATRIOT DAILY START UP - External Mix User Manual

Daily start up for patriot systems

Advertising
background image

PATRIOT

MAGNUM VENUS PRODUCTS

DAILY START UP FOR PATRIOT SYSTEMS

External Mix System


ACTIVITIES MUST BE DONE IN THE SEQUENCE SHOWN, AND MUST BE TICKED OFF AS

COMPLETED. USE THIS CHECKLIST IN CONJUNCTION WITH THE OPERATING MANUAL FOR THE

PATRIOT UNIT. THIS SEQUENCE FOLLOWS ON FROM

“FIRST TIME START-UP CHECKLIST –

EX

TERNAL MIX”


ACTIVITY

NO.

ACTIVITY

TICK WHEN
COMPLETED

Priority

Put on Respirator as specified for spray painting, Protective Clothing,
Eye Protection, and PVC Gloves

1

Check all hoses for damage.

2

Check all material supplies and fill or replace as needed.

3

Open recirculation valve on Catalyst Manifold

4

Open main inlet air valve on the manifold.

5

Remove the Pivot Pin from the catalyst drive.

6

Manually pump the catalyst pump with the catalyst drive, observe catalyst
returning to the catalyst jug, pump until the stream is air free.

7

Close recirculation valve on Catalyst Manifold.

8

Manually pump the catalyst pump with the Slave Arm drive, bring catalyst
pressure to operating pressure 100psi.

9

Check resin pump pressure, if needed slowly turn up the pump air pressure
to the operating pressure, 30

– 50 psi. If a safety over ride valve is installed

press and hold the priming button while adjusting air pressure

10

Replace the Pivot Pin into the catalyst pump drive.

11

Check atomizing air pressure, adjust as necessary.

12

Lubricate the nozzle o-rings, stud o-rings and gun front threads

13

Install nozzle and catalyst tip onto the gun.

THE UNIT IS NOW READY FOR USE


ABNORMAL CONDITIONS OBSERVED AND CORRECTED

Abnormal Condition

when
corrected




OPERATORS NAME _______________________________________ _DATE: ___________________

SIGN OFF WHEN START UP CHECKS ARE COMPLETED: __________________________________