Magnum Venus Plastech PATRIOT PRE-START CHECKLIST - External Mix User Manual

Pre-start checklist for patriot

Advertising
background image

PATRIOT

MAGNUM VENUS PRODUCTS

PRE-START CHECKLIST FOR PATRIOT

External Mix System


ACTIVITIES MUST BE DONE IN THE SEQUENCE SHOWN, AND MUST BE TICKED OFF

AS COMPLETED. USE THIS CHECKLIST IN CONJUNCTION WITH THE OPERATING

MANUAL FOR THE PATRIOT UNIT.


ACTIVITY

NO.

ACTIVITY

TICK WHEN
COMPLETED

Priority

Put on Respirator as specified for spray painting,
Protective Clothing, Eye Protection, and PVC Gloves

1

Tools and materials are available for pre-start checks.

2

Incoming airline is ½ inch.

3

Incoming airline is connected to the inlet manifold.

4

Ground straps are connected to the resin drum and to earth.

5

Incoming air valve is in the OPEN position.

6

Air supply is ON.

7

Remove nozzle cap, catalyst tip and nozzle.

8

Check for oil in the pump reservoir, fill 1/3 full.

9

Check that there is Catalyst in the Catalyst Bottle.

10

Check that the Catalyst Bottle Cap and Screen are in place.

11

Place the Resin Pick-up wand in the resin supply container.

12

Place the end of the Resin Return Hose in the resin container.

13

Remove air from the Catalyst feed line to the Catalyst Pump.

14

Close the ball valve below the Surge Chamber.


THE UNIT IS NOW READY TO BE STARTED UP. GO TO

– “FIRST TIME START UP – External Mix”


ABNORMAL CONDITIONS OBSERVED AND CORRECTED

Abnormal Condition

when
corrected


OPERATORS NAME _______________________________________DATE: _____________


SIGN OFF WHEN PRE-START CHECKS ARE COMPLETED: ____________________________


Advertising