Magnum Venus Plastech PATRIOT SPRAY FAN SETUP - Internal Mix User Manual

Spray fan setup for patriot

Advertising
background image

PATRIOT

MAGNUM VENUS PRODUCTS

SPRAY FAN SETUP FOR PATRIOT

Internal Mix System


ACTIVITIES MUST BE DONE IN THE SEQUENCE SHOWN, AND MUST BE TICKED OFF

AS COMPLETED. USE THIS CHECKLIST IN CONJUNCTION WITH THE OPERATING

MANUAL FOR THE ULTRAMAX UNIT. THIS SEQUENCE FOLLOWS ON FROM

“SET-UP

FOR CHARGABLE PATRIOT SYSTEMS

– Internal Mix”


ACTIVITY

NO.

ACTIVITY

TICK WHEN
COMPLETED

Priority

Put on Respirator as specified for spray painting, Protective
Clothing, Eye Protection, and PVC Gloves

1

Apply Red grease to the Mix Housing Threads.

2

Install the appropriate Spray Tip and Nozzle Cap onto the Mix Chamber
(do not over tighten as the lip of the mixer will be damaged)

3

Spray a test pattern onto a wide paper test strip. Observe the pattern.

Too wide with poorly defined “horns” – turn down the pump pressure

Too narrow but with well defined “horns” – turn up the pump
pressure.

Good width with well defined “horns” – optimized for low emission
spraying.

If more material is needed us a larger Spray Tip, do not increase

pump pressure to increase the amount of material.

Use a larger or smaller fan angle to adjust the width of the spray fan.

4

Note pressure settings, tip size, temperatures and materials for future
reference.

5

Flush the Mix Chamber with solvent

THE SYSTEM IS READY FOR PRODUCTION USE


FOR MORE INFORMATION ON ADJUSTING YOUR SYSTEM REFER TO THE “TESTING &
ADJUSTING MANUAL”.

FOR MORE INFORMATION ON PROPER TIP SELECTION REFER TO THE “MVP TIP CATALOG”


ABNORMAL CONDITIONS OBSERVED AND CORRECTED

Abnormal Condition

when
corrected



OPERATORS NAME _______________________________________ DATE: ______________


SIGN OFF WHEN SET UP CHECKS ARE COMPLETED: ______________________________