Magnum Venus Plastech System One FRP 4101-00-01 User Manual
Page 7
FRP SystemOne
Gelcoat
4
FRP SystemOne
CS1S1 Gelcoat Catalyst Surge
Chamber Disassembly
Chapter
3
1.
Loosen the 4101-18-1 (Jam Nut), and remove the 4104-8-1
(Gauge Adapter) from the 4104-4-1 (Surge Relief Valve Body).
2.
Remove and discard the 7301-4-013 (O-Ring).
3.
Remove the 4104-6-1 (Return Tube Fitting) from the 4104-4-1
(Surge Relief Valve Body).
4.
Remove and discard the 7301-4-013 (-Ring), and the 9201-1-4
(1/8” SS Ball).
WARNING
Before removing metering pump and catalyst surge chamber
assembly from teh slide drive, be sure to bleed the fluid
pressure from the system; before disconnecting any hoses or
tubes. System may be under pressure and could cause injury.
NOTE
This is all the disassembly that is required to install the repair
kit. Further disassembly is required if there is a problem with
the 8701-1-1 (Burst Disc).
NOTE
Once disassembly is complete all parts should be flushed in
distilled water and inspected for damage and replaced if necessary.