Magnum Venus Plastech System One FRP 3102-00-01 User Manual
Page 5
FRP SystemOne
Gelcoat
SystemOne Disassembly of
FS1.29S1 Gelcoat Fluid Section
2
Chapter
2
To remove the Fluid Section from the
SystemOne Unit:
1. Remove the 8401-5-1 (E-Ring), lift up the 8401-4-1 (Sleeve) and
remove the two 8401-3-1 (Connectors).
2. Remove the 4103-1-1 (Pivot Pin Guide Bushing) to disengage from
the 4103-7-1 (Slide Arm).
3. Remove the 7203-8-1 (Quick Pin) and slide the 4103-7-1 (Slide
Arm) out of the 3101-8-1 (Piston Rod Adapter).
When removing Resin Pump Fluid Section and Resin Surge Chamber, be
sure to bleed pressure from the system before disconnecting hoses or tie
rods. Release Surge Chamber charge before removing Surge Chamber.
System may be under pressure and could cause injury.
WARNING
NOTE
The resin pump can be rebuilt in place or easily removed from pump
column and moved to a workbench.