ANNUAL MAINTENANCE CHECKLIST:

PART

PROCEDURE

Ai

r Filter (“Water Trap”)

Drain. Repair any leaks or damage.

Gauges and Regulators

Check for damage and proper operation.

Accumulator

Remove and clean inside. Replace the O-Rings. Danger:
Never attempt to remove an accumulator until you have
relieved pressure.
See Accumulator & Filter section.

Filter

Clean and inspect filter screen for plugging. Note: Clean
the screen weekly and when changing from one material
to another. Use proper screen mesh size according to
the material being used.

Fluid Section

Replace the oil in the oil reservoir. Clean and dry the
silencers. Check piston rod, trip sleeve, cylinder head and
piston for wear or damage, replace as required. Replace the
O-Rings, piston cups and packing set. Rebuild lower
assembly.