Magnum Venus Plastech Flex Molding Process MKVI Mix User Manual

Page 40

Advertising
background image

MKVI Mix Meter System Operations Manual

Rev. 08/2013

Page | 40

To access the pump piston seal or any other internal parts pump proceed as follows.

1. Pump out catalyst / hardener from system and then remove feed pipe and filter

assembly from catalyst bottle / hardener container. Remove pump guard


2. Remove 4 M8 bolts (0559) from the Lower Block (1865) from pump body. The

pump Cylinder (1867) is now exposed. Remove this by withdrawing down to
expose the pump shaft and piston assembly.

3. Remove the Piston retainer/lower Seal Retainer (1870) to allow removal of back

bush (1873) and the Piston Seal (3644).

4. Replace with new S

eal. Observe the correct” lip up” orientation of the seal as

detailed on drawing.


Reassembled in the reverse order

Pump Piston shaft seal:

Do not attempt to remove the top Piston Rod Clevis (4278) from the shaft as this is
permanently thread locked together.

The top Seal (3363) can be removed and replaced by following the above description to
remove the pump and disassembly.

1. The Piston assembly (1869) must be removed so that the piston rod can be

withdrawn upwards through the top Seal Housing (1866) and removed to access
Piston Rod Seal (3363).

2. Remove Circlip (3392) and Retainer Washer (1874) and old Seal (3363).

3. Ensure new Seal (3363) is evenly pushed into the top housing with the seal lip

entering first.

4. Reassemble in reverse order.


Note: when replacing piston assembly ensure M8 stud (4087) remains as factory
set in Thread sealed position as indicated.

When using Ball Spring the Stud (4087) should be thread locked in position to
dimension 23.5mm when spring used or dimension 17mm when no spring is used.