Magnum Venus Plastech STAINLESS STEEL CHOP CHECK CCPLS-1000-SS User Manual

Page 3

Advertising
background image

CHAPTER

1










STAINLESS STEEL CHOP CHECK PUMP FLUID SECTION
DISASSEMBLY



WARNING: When removing Pump Fluid Section, Hoses and Resin
Surge Chamber, be sure to bleed off fluid pressure from the system
before disconnecting. Release Surge Chamber charge before
removing Surge Chamber. System may be under pressure and cause
injury.

Note: The Fluid Section can be rebuilt in place or easily removed and taken to a
workbench. Flushing the fluid section with suitable cleaning agent can make
the rebuild process much easier.


TO REMOVE THE FLUID SECTION FROM THE PUMP ASSEMBLY:

1.

Put the pump into the lowest position of the down stroke.

2.

Disconnect the resin hose from the side of the Pump fluid section.


Warning: Be sure to remove fluid pressure from the system before disconnecting

resin hose, tie rods or surge chamber. System may be under pressure and can
cause injury.


3.

Remove the E-Ring (APP-9102), lift up the Sleeve (APP-9109) and remove the two
Connectors (APP-9096).

4.

Remove the four Hex Head Bolts (02705-14) holding the fluid section to the Pump
Mount Plate (CCP-1008).

5.

Remove the four Hex Head Bolts (F-HB-06C-16) holding the fluid section to the
Support Plate (CCP-1009).

6.

Remove the two Hex Nuts (7201-1-12) from the Support Rod (APD-1003)

7.

Shift the Ram Control valve into the Ram up position, move the ram up until the pump
mount plate will allow the pump fluid section to be removed.



Note: As you disassemble, lay the parts out on a towel or rag in the order you take

them apart. This will help you remember how they go back together. Inspect
each part for wear or damage and note parts that require replacement.



FLUID SECTION DISASSEMBLY PROCEDURE:

Advertising