Magnum Venus Plastech CB-8000-xxx Resin Monitor User Manual

Page 16

Advertising
background image

INSTALLATION AND OPERATIONS MANUAL

CB-8000-XXX

MAGNUM VENUS PLASTECH

REV 1.05

APRIL 2013

PAGE 16

Press the PAR key.***

COUNTER A SCALE FACTOR

Display will read

A-ScF.

Scale Factor entry.

At this point you will have the option to set

the scale factor for calibration. Press the

SEL key if you wish to set the scale factor.

Press the SEL key to adjust the number and

use the RST key to move from number to

number. Please see Chapter 5-Calibration

section for setting this number.

Press the PAR key.

COUNTER A RESET ACTION

Display will read

A-rST.

Default setting

should be

ZEro

.

Press the PAR key.

COUNTER A COUNT DIRECTION

Display will read

A-dir.

Default setting

should be

NOr

.



Press the PAR key.

COUNTER A COUNT LOAD VALUE

Display will read

Cnt-Ld.

Default setting

should be

50.00

. This setting has no

bearing on this programming.

Press the PAR key.

COUNTER B BATCH COUNT ENABLE

Display will read

b-bAt.

Default setting

should be

NO

.


Press the PAR key.

COUNTER RESET AT POWER-UP

Display will read

r P-UP.

Default setting

should be

NO

.


Press the PAR key.

USER INPUT FUNCTION

Display will read

Usr-INP.

Default setting

should be

rESET

.


Press the PAR key.

Display will read

Pro or No

.


Press the PAR key.

This will exit programming mode.






*** Note: MVP recommends no more than 2 decimal points be used.