Cipher Gun

3.

Install Flush Valve Assembly (5104-01-01) into resin side of Gun Block

4.

Install Distribution Ring (5104-17-1), with larger holes to the back, into the Mix
Housing (5104-20-1)

5.

Install new Mix Housing Seal (5104-12-1) into Mix Housing (5104-20-1)

6.

Insert Catalyst Injector Assembly (5104-03-01) into Distribution Ring (5104-17-1)

7.

Attach Mix Housing (5104-20-1) to Gun Block (CPR-2001-1) using the two (2) Cap
Screws (F-CS-1024-09).

8.

Install new O-Ring (O-S-012) into Catalyst Needle Seat area of the Gun Block

9.

Install new O-Ring (O-S-012) on Catalyst Needle Housing (CPR-2012-01) and
thread into Gun Block

10. Install new O-Ring (O-S-012) into Resin Needle Seat area of the Gun Block
11. Install new O-Ring (O-S-012) on Resin Needle Housing (CPR-2004-01) and thread

into Gun Block, lightly grease threads.

12. Install new O-Ring (O-S-006) onto both of the Piston Needles (CPR-2005-01)
13. Insert one Piston Needle (CPR-2005-01) each into the Catalyst Needle Housing

(CPR-2012-01) and Resin Needle Housing (CPR-2004-01)

Gun Handle Assembly (54350-3)

1.

Apply lubricant to Springs (04039-1) and insert into Gun Handle (54350-3)

2.

Thread Spring Retainers (54000-1) over Springs (04039-1) into Gun Handle (54350-
3)

3.

Slide Spring (04070-1) onto the end of the Poppet Assembly (MG-2031)

4.

Insert Poppet Assembly (MG-2031) into Valve Body (54440-1)

5.

Slide O-ring (O-S-104A) over Poppet Assembly (MG-2031) and retain with Packing
Retainer (54420-1)

6.

Screw Assembled Valve Body (54440-1) into the Gun Handle (54350-3)

Catalyst Injector Assembly (5104-03-01) Assembly

(See drawing Injector Assembly (5104-03-01) for reference)

1.

Slide Injector Plunger (5104-16-1) thru Injector Body (5104-15-1)

2.

Slide Compression Spring (9203-2-2) over Injector Plunger (5104-16-1)

3.

Screw Plunger Retainer (5104-14-1) onto Injector Plunger (5140-16-1)

4.

Install new Injector Seal (5104-13-1) onto Injector Body (5104-15-1)

Assembly Gun Head (CPR-2001-01) and Gun Handle (54350-3)

1.

Attach the Gun Block Assembly (CPR-2001-01) to the Gun Handle (54350-3) using
Cap Screw (F-CS-04C-12).

2.

Slide Trigger (54360-1) into place against the needles and line up the holes with
the handle.

3.

Push Trigger Stud (54630-1) thru both the Trigger (54360-1) and the Gun Handle
(54350-3) and retain with Screw (00145).