Mallory Ignition Mallory INLINE RETURN REGULATOR4316 User Manual

Inline return regulator, Installation instructions, Part no. 4316

Advertising
background image

®

70, 110, OR

140 PUMP

®

INSTALLATION INSTRUCTIONS

INLINE RETURN REGULATOR

PART NO. 4316

1. Mallory’s Inline Return Regulator is an adjustable

bypass style fuel pressure regulator designed to

regulate pressure in a carbureted fuel system.

2. The regulator must be mounted in the return line.

For best results, the regulator should be mounted

within 3 feet of the carburetor(s). See Figure 3 for

typical installations.

3. Fuel pressure is adjusted by loosening the jam nut

and turning the adjustment screw. The adjustment

range is approximately 3-12 PSI. Exact range depends on

the size of the fuel pump and return line (see Figure 1).

4. This regular is designed to work with pumps up to 300 GPH.
5. Fittings are included to connect the regulator to –8AN fuel

lines. Alternate fittings may be used to connect the regula-

tor to other sizes/types of fuel lines.

6. Repair kits are available and include all necessary o-rings.

These kits can be used for repair, or to convert from gaso-

line to alcohol.
Use Kit #3173 for gasoline applications

Use Kit #3174 for alcohol applications.
Lubricate o-rings prior to assembly.

7. This regulator is assembled with o-rings for use with gaso-

line. O-rings are included for use with alcohol. If alcohol fuel

is used, disassemble the regulator and replace the o-rings

with those supplied.

8. Because this is a return style regulator, the bypass at the

pump must be disabled. If you are using a pump with an

external bypass (such as Mallory 250), place a plug in the

bypass outlet.
If you are using a Mallory 70, 110, or 140 pump, the bypass

spring must be replaced with the bypass spacer included

with this regulator (see Figure 2). Replace the spring with

the spacer. Apply thread sealant to the bypass plug and

tighten the plug until snug. Do not overtighten. Replace and

tighten the jam nut (see Figure 2).
If you are using a non-Mallory pump, contact the manufac-

turer for information on how to disable the bypass.

FEED LINE SIZE

Up to 500 HP: –6AN or 3/8" Hardline

Up to 750 HP: –8AN or 1/2" Hardline

Up to 1250 HP: –10AN or 5/8" Hardline
RETURN LINE SIZE

Up to 90 GPH: –6AN or 3/8" Hardline

Up to 200 GPH: –8AN or 1/2" Hardline

Up to 300 GPH: –10AN or 5/8" Hardline

FORM 1548 (REV. A) 05/02