Where “w:yz” refers to the quantity for the vehicle selected. The machine will be ready to enter the correct quantity of refrigerant. Confirm by
pressing the ENTER key.
Open the high and low service valves on the machine and press the START key (in the case of an A/C system with a single high or low pressure
coupling, open only the relative valve on the machine).

NOTE: Charging may not run to completion due to pressure balance between the internal tank and the A/C system. If this occurs, close the valve

on the high pressure quick connect coupling (leaving the low-pressure side open), turn on the vehicle and switch on the A/C system. The unit is
equipped with a tank heater to limit this occurrence. When the charging operation is complete, the machine will display the following dialog
boxes:

END OF CHARGE

CLOSE HIGH AND LOW

VALVES ON MACHINE

START: TO CONTINUE

START ENGINE

TURN ON A/C SYSTEM

START: TO CONTINUE

CHECK HIGH AND LOW

A/C SYSTEM PRESSURES

START: TO CONTINUE

CLOSE HIGH PRESSURE

COUPLER

START: TO CONTINUE

OPEN HIGH AND LOW

VALVES ON MACHINE

TURN ON A/C SYSTEM

START: TO CONTINUE

ALLOW HIGH AND LOW

PRESSURE TO EQUALIZE

CLOSE ALL VALVES

RESET: WHEN COMPLETE

LAST RECOVERED QUANTITY

To see how much refrigerant was recovered during the last recovery phase.

AUTOMATIC PROCEDURE

ASSISTED PROCEDURE

<NEXT MENU>

Ref avail X,XX lb

Select NEXT MENU:

<LAST RECOVERED QTY>

TANK CHARGING

AIR PURGE

DATA AND CONFIGURAT.