Refrigerant Detected:

R134a


Pass/Fail Purity:

95%


Power:

12—15 VDC @ 1 amp


Sample Source:

Oil Free Vapor Refrigerant


Minimum Input Pressure:

1.38 Bar (20 Psig)


Maximum Input Pressure:

20.70 Bar (300 Psig)


Operating Temperature :

10°— 45°C


Approvals (Pending):

UL, CE, SAE J1771


Replacement Oil Filter P/N:

6-01-6001-23-1