Air supply and con- nections – MAX HS130(CE) User Manual

Page 8

Advertising
background image

8

RECOMMENDED OPERATING PRES-

SURE:

17 to 23 bar (250 to 320 p.s.i.). Select the oper-
ating air pressure within this range for best fas-
tener performance.
DO NOT EXCEED 23 bar (320 p.s.i.).

4. TECHNICAL DATA
1 NOISE

A-weighted single-event sound power level

------ LWA, 1s, d 101.5 dB

A-weighted single-event emission sound
pressure level at work station

------- LpA, 1s, d 92.0 dB

These values are determined and docu-
mented in accordance to EN12549 : 1999.

EAR PROTECTION MAY BE REQUIRED IN
SOME ENVIRONMENTS
As the working condition may include exposure to
high noise levels which can lead to hearing dam-
age, the employer and user should ensure that
any necessary hearing protection is provided and
used by the operator and others in the work area.

2 VIBRATION

Vibration characteristic value = 6.6 m/s

2

These values are determined and document-
ed in accordance to ISO 8662-11.
This value is a tool-related characteristic val-
ue and does not represent the influence to the
hand-arm-system when using the tool. An in-
fluence to the hand-arm-system when using
the tool will, for example, depend on the grip-
ping force, the contact pressure force, the
working direction, the adjustment of mains
supply, the workpiece, the workpiece support.

5. APPLICATIONS

∗ Roof, Floor and Wall framing
∗ Truss framing

3. AIR SUPPLY AND CON-

NECTIONS

Read section titled "SAFETY IN-

STRUCTIONS".

DO NOT USE ANY POWER SOURCE EXCEPT
AN AIR COMPRESSOR
The tool is designed to operate on compressed
air. Do not operate the tool on any other combus-
tible gases (e.g., oxygen, acetylene, etc.) since
there is the danger of an explosion. For this rea-
son, absolutely do not use anything other than
an air compressor to operate the tool.

OPERATE WITHIN THE PROPER AIR PRES-
SURE RANGE
The tool is designed to operate within an air
pressure range of 17 to 23 bar (250 to 320 p.s.i.).
The pressure should be adjusted to the type of
the work being fastened. The tool shall never be
operated when the operating pressure exceeds
23 bar (320 p.s.i.).

WARNING

17 bar

250 psi

23 bar

320 psi