Options, Technical speci fications, Approved – MaxPower Corp GE LP11 Series User Manual

Page 2: Remote monitoring and diagnostics via, Or internet, Input and output, Available for 5-10k, Sizes > three available slots for options, Plug-in card, potential- free relay contacts, It: any single

Advertising
background image

Options

> Remote monitoring and

diagnostics via

LAN

or internet

>

UPS

management software

facilitates operation and
maintenance of the

UPS

> Input and output

PDU

available

for 5-10k

VA

sizes

> Three available slots for options:

SNMP

plug-in card, potential-

free relay contacts

RPA

K

it: Any single

UPS

can

be easily

field-configured for

Redundant Parallel Architecture

RS

-232/contact interface,

providing maximum flexibility

> Dual

AC

input option

> Additional external matching

battery cabinets are available for
extended runtime requirements
(Contact the factory for details)

Technical Speci

fications –

UL

approved

Height

Width

Depth

Enclosure A

26.8" (68 cm)

12.3" (31.2 cm)

28.7" (72.9 cm)

Enclosure B

39.2" (99.6 cm)

12.3" (31.2 cm)

28.7" (72.9 cm)

Table 1

Models

LP-11U - 5

LP-11U - 5

LP-11U - 6

LP-11U - 6

LP-11U - 8

LP-11U - 10

(120V)

(120V)

Rating (VA/W)

5000 / 4000

5000 / 4000

6000 / 4800

6000 / 4800

8000 / 6400

10,000 / 8000

Backup Time @ 50% / 100% loads

25 / 10 min.

25 / 10 min.

20 / 8 min.

20 / 8 min.

29 / 11 min.

22 / 8 min.

Enclosure (Table 1)

A

B

A

B

A

A

Net Wgt Incl. Batteries (kg/lbs)

134 / 295

175 / 386

134 / 295

175 / 386

175 / 386

186 / 410

Input Voltage (VAC)

Nominal (V)

208

120

208

120

208

208

Range @ 100% Load (V)

162-285

81-141

162-285

81-141

162-285

162-285

Range @ 50% Load (V)

146-285

72-141

146-285

72-141

146-285

146-285

Input Power Factor

.99

Input Frequency (Hz)

40-70

Output Power Factor

.8

Output Voltage (VAC) (sinusoidal)

120+208+220/230/240 User Selectable

Output Frequency (Hz)

50 / 60 (Selectable)

Output Voltage Regulation

+/- 1%

Output THD at Linear Load

< 1%

Output THD at Non-linear Load

< 2%

Crest Factor Handling Capacity of a Non-linear Load

5:1

Overload Capability on Inverter

110% 20 min., 130% 3.5 min., 150% 2 min.

Color

Front bezel: Aluminum Grey (RAL 9006); Cabinet: White (RAL 9003)

Environment Protection

IP20 (IEC 60529 & DIN 40050)

Operating Temperature / Humidity – UPS

14° F - 104° F (-10° C - 40° C) / 95% Non-condensing

Audible Noise

40-50 dBA - 3.3 feet (1 meter)

Safety Classi

fications & Listings

UL, cUL 1778; EN50091-1-1; EN 60950; IEC 62040-1

EMI

FCC Part 15 Class A / EN50091-2, IEC/EN 62040-2 Class A

Surge Protection

IEC 61000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2

Connectivity

RS-232; programmable alarm contacts (optional); SNMP (optional)

Warranty

24 months after seller’s shipment to customer *

* Extended Warranties available

Represented by:

GE D

igital Energy –

Power Quality

701

E 22nd Street

Lombard, IL 60148 USA

800 637 1738

www.gedigitalenergy.com/ups

Information subject to change
without notice. Please verify
all details with GE.
© 2009 General Electric Company
All Rights Reserved

GEA

-D

2003 (9/09)