Ocr0008, Displays and entries – Micromod MOD: Modcell 2050R Quick Reference Guide User Manual

Page 2

Advertising
background image

operator accesses 12 menus through the setup keys

summarized in the chart on the reverse side. For

• Moves through the basic

Scroll:

• Advancestostepl.

* BRD CALIBRAT

• Enters a YES response.

ARE YOU SURE?

YES, NO (If YES, all configura-

or SKIP LOCKOUT

RAT BIAS TYPE

RATIO, BIAS, RAT BIAS

SEG 1 SOAK TIM

XXX. X (0 to 3000.0 hours or

Down: • Moves down through

tion data is written over with

TOTALIZE DI1 FUNC

RUN/STOP, RUN/RSET,

RATIO SOURCE

LOCAL, REMOTE

minutes)

menus.

factory default values)

RUN/HOLD (See IB-23C650)

BIAS SOURCE

LOCAL, REMOTE

SEG 1 RMP RATE

XXX. X (Change per unit time in

• Decreases values.

CONFIG CHANGED

For information only

R/H, RSET LOCKOUT

YES, NO (See IB-23C650 for

RATIO BALANCE

STANDARD (May bump when

engineering units)

• Enters a NO response.

SOFTWARE VERSION

For information only

or RESET LOCKOUT

explanation)

switching manual to auto),

SEG 1 RELAY A

ON, OFF

DISPLAY VERSION

For information only

or RUN/HOLD LOCKOUT

AUTO (Bumpless Transfer)

SEG 1 RELAY B

ON, OFF

Top/Middle Display

Bottom Display/Entry

R/L KEY LOCKOUT

YES, NO

Not valid if source is remote.

SEG 1 RELAY C

ON, OFF

BASE CFG **MENU**

INPUTS **NENU*

LOC-REM ALLOWED

NO, YES

BIAS BALANCE

Same entries as Ratio

SEG 1 GUARANTD

NO, YES

MAIN PWR FREQ

60 HERTZ, 50 HERTZ

DECIMAL POINT

0., 0.0, 0.00, 0.000

DIG IN 1 ACTION

REVERSE, DIRECT

Balance

SEG 2 SETUP

Entry point for Segment 2.

PROC INP TYPE

MILLIAMP (0 to 54 mA dc),

PROC INP SETUP

Entry point for input setup

DIGITAL INPUT 2

Entry point for Digital Input 1.

RATIO SOURCE

LOCAL, REMOTE. For ratio and

Same steps as for Segment 1.

VOLT (0 to 6V dc),

PRC TEMP UNITS

CELSIUS, FAHRENHT

Same steps as Digital Inpu 1.

Bias type. Only one remote

Repeat for Segments 3-10.

THERMCPL (Thermocouple),

PROC INP MA. HI

XX. XX (1.00 to 54.00 mA dc),

DI SETPT SEL LIST

(15 combinations available,

source allowed.

RTD (RTD Input),

or MV. HI

XX. X (0 to 120 mV dc),

see IB-23C650 for listing)

BIAS SOURCE

LOCAL, REMOTE. For ratio and

TOTALIZE **MENU**

MILLIVLT (-10 to 120 mV dc)

or VOLTS. HI

X.XX (0.00 to 5.OOV dc)

Bias type. Only one remote

WRAP AT PRED CNT

NO (Counts until turned off or

SLIDEWIR (0 to 100% slide-

PROC HI POSITION -

X .XXX (0.000 to 1.000)

MA. OUTP **NENU*

source allowed.

max. count reached),

wire wiper position)

PROC INP MA. LO

OUTPUT MA. HIGH

XX.X (01.0 to 54.0 mA dc)

RATIO BALANCE

For Ratio and Bias type. Same

YES (Counts to predetermined

PROC INP IC TYPE

TYPE * (J, K, E, R, 5, T, B, N)

or MV. LO

XX. XX (0.00 to 53.00 mA do).

OUTPUT MA. LOW

XX.X (0 to mA High less 1 mA dc)

entries as Ratio Balance.

count & wraps to preset value)

PROCESS TEMP CAL

Entry point tor temperature

or VOLTS LO

XX.X (-10.0 to llOmVdc).

HEAT OUT HI LIMIT

XX.X (0.1 to 110.00/0 of heat

BIAS BALANCE

For Ratio and Bias type. Same

INPUT THRSHOLD

XXXX (0 to Engineering Units

correction

PROC LO POSITION

XXX (0.00 to 4.90 V dc)

output span)

entries as Ratio Balance.

High Value, in eng. units)

PR TEMP= XXX.X

XX.X (XXX.X = Process tem-

XXXX (0.000 to 0.900)

COOL OUT HI LIMIT

XX.X (0.1 tO 110.0% of cool

TOTALIZE IS OFF

For information only

perature, XX.X = Temperature

PROCESS LIN TYPE

NONE, SQR ROOT

output span)

SETPTS **MENU**

or IS ON

correction [+15 to -15])

PROC ENG UNITS HI

XXXX (-3000 to 30000)

OUTPUT HI LIMIT

XX.X (10.0 to 110% of mA

LOC SETP

Entry point for set-point setup

TOTALIZE DIRECT

UP, DOWN

INPUT 2 ENABLE

NO, YES

PROC ENG UNITS LO

XXXX (-3000 to 30000)

output span, 10.0 to 100% of

LOC SETP FIXED

NO, YES

TOTALIZE RATE

PER SEC, PER MIN, PER HOUR

INPUT 2 TYPE

Same steps as Input1 type

PR FAULT OUTPUT -

XX (0 to 100%)

relay output span)

LOC SETP HI LIMIT

XXXX (Low limit to 30000)

SCALE DEC PT

0., 0.0, 0.00, 0.000

PR FAULT LEVL PCI

XX (0 to 100%). See

OUTPUT LO LIMIT

XX.X (-8% or 0% relay to

LOC SETP LO LIMIT

XXXX (-3000 to high limit)

SCALE FACTOR

XXXX (0.001 TO 30000)

OUTPUT TYPE

CUR PROP (Current prop.),

IB-23C650 for limits

high limit less 1.0%)

LOC SETP INIT VAL

XXX X (Low limit to high limit)

PRESET VALUE

XXXXXXX (.000 to 9999999)

POS PROP (Position prop.),

RECOVERY OPTION

MANUAL, LAST

LIMIT IN MANUAL

NO, YES=Limits apply in Manual

SETPT 2

Entry point for set-point 2

FREDETRD COUNT

XXXXXXX (.000 to 9999999)

HC/RR (Heat/Coo/, dual relay),

POWER UP OUTP SRC

LAST, FIXED

SETPT 2 ENABLE

NO, YES

HC/CR (HeatiCool, mA/relay),

INPUT 2 SETUP

Same steps as Process Input1

FIXED PWR UP OUTPT

XX.X (-8.0 to 110.0, within Out-

ALARMS **MENU**

HC/CC (Heat/Cool, dual mA),

Setup thru Eng. Units Low

put high and low limits)

SETPT 2 FIXED

Same steps as Set-point 1

BEEP ON OCCUR OF

NONE, or any combination of:

ON/OFF (On,Off),

I2 FAULT ACTION

NONE, LOCAL (Controller put in

Fixed thru Initial Value.

DG, P1, P2

TIM PROP (Time pro port.)

auto mode with fault value)

RETRANS VARIABLE

PROCESS, SETPOINT,

Repeat for Set-points 3 and 4

ALARM ACK REQD ON

NONE, or any combination of:

POS PROP has position choice

NONE (Fix output 2 at 0 mA)

POWER UP SETP SRC

LAST, LOC SETPT. SETPT 2,

DG, P1, P2

CONTROL ACTION

DIRECT, REVERSE

I2 FAULT VALUE

XXXX (-3000 to 30000)

RETRANS PROC HI

XXXX (-3000 to 30000) Decimal

SETPT 3, SETPT 4, REM SETP

OVERCFGD DIAG ON

YES , NO

MA. OUTP ACTION

DIRECT, REVERSE

I2 FAULT LEVL PCI

XX (0 to 100%)

or SETPT HI

placed per "Inputs" Menu.

INPUT 2 MISSING

Warning message. times out in

P1 RELAY ACTION

LATCHING (relay releases

HEAT OUT ACTION

DIRECT, REVERSE

RETRANS PROC LO

XXXX (-3000 to 30000) Decmal

1 second.

when alarm acknowledged),

COOL OUT ACTION

DIRECT, REVERSE

ENG UNIT LABEL

XXXX (X=any character in Tag

or SETPT LO

placed per "Inputs" Menu.

FIXD PWR UP SETPT

XXXX (-3000 to 30000, within

NO LATCH (relay releases

VALVE CALIB

See IB-23C650.

Name field in Tune menu)

local set-point limits)

when alarm condition not

HOLD PWR UP MSG

NO, YES (Hold ‘POWER

RIGHT BAR

OUTPUT (Output displayed)

OUTPUT 2 MA. HIGH

XX. X (01.0 to 54.0 mA dc)

SETPOINT TRACKING

NO, YES (Note: Remote set

present)

FAILED’ message at startup)

DEVIATN (Deviation displayed)

OUTPUT 2 MA. LOW

XX. X (0 to 53.0 mA

point cannot track)

POWER UP MODE

LAST, AUTO, MANUAL

0EV BAR FULL SCL

XX (1 to 100% of span)

DISPLAYS AND ENTRIES

Top/Middle Display

Bottom Display/Entry

Top/Middle Display

Bottom Display/Entry

Top/Middle Display

Bottom Display/Entry

Top/Middle Display

Bottom Display/Entry

RAT BIAS ENABLE

NO, YES

DIG INPT **MENU**

RELAYS **MENU**

RAMPSOAK **MENU*

The MODCELL 2050 generates display prompts to

AUTOTUNE ENABLE

NO, YES

DIGITAL INPUT 1

Entry point for Digital Input 1.

RELAY A SETUP

Entry point for Relay A setup

RAMPSOAK REPEAT

NO, YES

make setup and operation fast and easy. The

RAMPSOAK ENABLE

NO, YES

DIG IN 1 FUNCTION

NONE, AUTO/MAN, ALRM ACK,

RELAY A FUNCTION

NONE, ALARMS, TOTALIZE,

SOAK HYST

XXXX (0 to 30000)

TOTALIZE ENABLE

NO, YES

TOTALIZE, RAMPSOAK,

RAMPSOAK, REM/LOC,

RAMP HYST

XXXX (0 to 30000)

described below. The sequence of menus is

RS-485 ENABLE

YES, NO

SETP SEL

AUTO/MAN

RAMPSOAK IS OFF

For information only

TUNE PASSWORD

XXXX (Enter this value [0 to

DIG A-M OUT ENAB

NO, YES

RELAY A TRIP ACT

On alarms 1, 2, 3, 4, 12, 13

or IS ON

more detailed information, see IB-23C650.

30000] in ‘Displays’ menu)

DIG A-M OUT VAL

XX.X (0 TO 54.0 mA)

14, 23, 24, 34, 123, 124, 134,

RAMPSOAK UNIT TIM

MINUTES, HOURS

CONFIG PASSWORD

XXXX (Enter this value [0 to

A/M KEY LOCKOUT

YES, NO

234, 1234

RAMPSOAK SEGMENTS

XX (0 to 10)

30000] in Displays menu)

MAN-AUTO ALLOWED

NO, YES

RELAY B SETUP

Same steps as Relay A Setup.

SEG 1 SETUP

Entry point for Segment 1

setup steps.

CHK SUM DATABASE

YES (ARE YOU SURE?), NO

RAMPSOAK DI1 FUNC

RUN/STOP, RUN/HOLD,

RELAY C SETUP

Same steps as Relay A Setup.

SEG 1 START SP

XXXX (Local Set-point Low Limit

See IB-23C650.

RUN/SKIP (See IB-23C650)

to Local Set-point High Limit)

Up: • Moves up through menus.

DEFAULT DATABASE

Up key requests default

R/H, RSET LOCKOUT

YES, NO (See IB-23C650 for

RS-485 **MENU*

See IB-23C650M

SEG 1 END SP

XXXX (Local Set-point Low Limit

• Increases values.

LOCK CFG MENUS

NO=Reaci access, YES

or RUN/HOLD LOCKOUT

explanation.

RAT BIAS **MENU**

to Local Set-point High Limit)