Health physics division, Dosidef_access module for restricted access to the, Dosixom fi les data transfer to the server – Mirion Technologies DOSIDEF User Manual

Page 2: Local data enrichment (mission defi nition), Local and utc time management for synchronizing, Readers local back-up, Populate reader with pre-allocation lists, Evaluation of the daily dose exposure and duration, Raw and net doses calculation, Background compensation capability

Advertising
background image

Mirion Technologies (MGPI) Inc

5000 Highlands Parkway

Suite 150

Smyrna Georgia 30082

USA

T +1.770.432.2744

F +1.770.432.9179

Mirion Technologies (MGPI) SA

BP 1

F-13113 Lamanon

France

T +33 (0) 4 90 59 59 59

F +33 (0) 4 90 59 55 18

Mirion Technologies (RADOS) Oy

P.O. Box 506

FIN-20101 Turku

Finland

T +358 2 468 4600

F +358 2 468 4601

Mirion Technolgies (RADOS) GmbH

Ruhrstrasse 49

DE-22761 Hamburg

Germany

T +49 (0) 40 851 93-0

F +49 (0)40 851 93 256

Health Physics
Division

Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.

DOSIDEF

Active Dosimetry - Software

www.mirion.com

144643EN-B

SYSTEM ARCHITECTURE

DOSIDEF_ACQUISITION module for data collection

DOSIDEF_ACCESS module for restricted access to the

central database

DOSIDEF_CALC module for the dose calculation and

the database management

The 3 modules can be operated separately or on the

same PC

DOSIDEF_ACQUISITION MODULE

Data collection from deployed XOM readers or

DOSIXOM fi les

Data transfer to the server

Local data enrichment (mission defi nition)

Local and UTC time management for synchronizing

readers

Local back-up

Populate reader with pre-allocation lists

DOSIDEF_CALCULATION MODULE

Collected data analyzed prior to integration in the data-

base

Rebuilds chronology, detects and solves any problem

due to missing data or erroneous sequence of events

Residual, gamma fl ash and neutron fl ash doses management

Evaluation of the daily dose exposure and duration

Raw and net doses calculation

Background compensation capability

Dose compared with the preset limit thresholds

DOSIDEF_ACCESS MODULE

Administrative data management and display of the

dosimetry for individuals, cells, units or missions

Display all events occured on the fi led (readings)

Alarms and exceeded limits sorting

Data enrichment capability

XOM pre-allocation lists managment

Access to the dosimeter database for maintenance

purposes

Large choice of built-in reports

SYSTEM CONFIGURATION

PC-based confi guration for clients

Server size depends on population

Operates with Windows 98, 2000, XP

Compatible with ORACLE® and SQL_server® data

bases (not included)

Advertising