Health physics division, Description, 3 sided lead shielding – Mirion Technologies SPIR-Ident Vehicle G User Manual

Page 2: Remote cameras control option, With or without occupancy signal functions, Gamma detection and identification capability

Advertising
background image

Health Physics

Division

Since norms, specifications and designs are subject to occasional change, please ask for confirmation of the information given in this publication.

Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179

Mirion Technologies (MGPI) SA
Lieu-Dit Calès,
Route d’Eyguières
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18

Mirion Technologies (RADOS) Oy

P.O. Box 506
FIN-20101 Turku
Finland

T +358 2 468 4600
F +358 2 468 4601

Mirion Technologies (RADOS) GmbH

Ruhrstrasse 49
DE-22761 Hamburg
Germany

T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256

Mirion Technologies Shanghai Branch

Room 801, 78 Jiangchang
San Lu, Zhabei District
Shanghai 200436
China
T +86 21 6180 6920
F +86 21 6180 6924

SPIR-IDENT VEHICLE - G

Detection and Identification - Risks Prevention

www.mirion.com

144207EN-E

DESCRIPTION

1 to 4 detection pillars including each a 2 or 4 liter
NaI(Tl) gamma detector

3 sided lead shielding

Each gamma detector is associated with a fast digital
spectrometer

Standard or Panel PC with SPIR-IDENT Server software,
Portal and Expert mode interface

Includes SIA identification algorithm designed for
challenging Homeland Security issues

Remote cameras control option

With or without occupancy signal

FUNCTIONS

0.5 second continuous elementary spectra acquisition
and sourceless stabilization

Count rate and dose rate calculation, alert criteria
monitoring

Real-time identification per channel and group of
channels

Spectra accumulation during occupancy for preset time
with resume capability

Automated report per measurement including pictures
(user comments can be included)

Sliding spectra analysis between occupancies to
monitor background and for vehicle profile analysis

PERFORMANCES

Isotope list:
according to ANSI N42-38, IEC and IAEA standards
Industrial, SNM, Medical and NORM radionuclides

Gamma detection and identification capability:

according to configuration, designed to exceed ANSI
N42-38 (vehicle, static mode)

example: identifies 10 μCi 137Cs shielded with
3 cm (1.1 in) iron (ANSI requirement: 85 μCi)

includes special processing for shielded or masked
isotopes for example SNM masked by medicals or
NORMs

COMMUNICATION

Ethernet (network) connectivity

DIMENSIONS (PER PILLAR)

Body: 148 x 50,2 x 22,2 cm (57 x 19,73 x 8,74 in)

Base: Ø 32 cm (12.6 in)

Weight: 58 kg (128 lb)

Expert mode display

Portal interface detailed results

Vehicle Portal interface display

Advertising