Mityvac 04095 DUAL CONVERTER User Manual

Dual converter, Installation instructions

Advertising
background image

Form 822363

FEBRUARY 2003

DUAL CONVERTER

TM

INSTALLATION INSTRUCTIONS

NOTE:READ THROUGH ALL INSTRUCTIONS AND FAMILIARIZE YOURSELF WITH THE PARTS
PRIOR TO INSTALLING YOUR DUAL CONVERTER

One Lincoln Way

St. Louis, MO 63120-1578

USA

Phone +1.314.679.4200

Fax +1.800.424.5359

© Copyright 2003
Printed in USA

Web site:
www.lincolnindustrial.com

1. Make sure the exterior of your pump is cleaned of loose

dirt, grease, oil, etc.

2. Remove the old exhaust fitting

a. For plastic pump: Retain screws
b. For metal pump: Discard screws

3. Remove the old junction

a. For plastic pump: Retain screws
b. For metal pump: Retain screws

4. Install black exhaust valve in elbow. Install the elbow on

the pump. Do not overtighten.
For plastic pump: Use screws retained in step 2a.
For metal pump: Use the two larger screws provided.

a. For plastic Dual Converter

TM

(p/n 06895):

Select the correct exhaust elbow from the Dual
Converter

TM

kit. (The elbow marked “M” is for the

metal pump; the one marked “P” is for the plastic
standard pump; the one marked “SP” is for the plastic
Superpump

TM

).

b. For Silverline

TM

(metal) Dual Converter

TM

(p/n 04095):

Use the exhaust elbow provided in kit.

5. Slip the small O-ring onto elbow. Install the large O-ring

into Dual Converter

TM

frame. Slide the Dual Converter

TM

into place on the pump body and elbow. Make sure the
elbow is fully seated and the frame is snug against the
body. Install rear screw (on side away from knob) and
tighten until just snug. Use one of the screws retained in
step 3.

6. Turn knob to “Vacuum” position. (Note the large square

notch on rear side of the black rotary valve is pointing up,
toward elbow.)
Remove the screw from knob, then
remove the knob from the shaft.

7. Slowly slide the black rotary valve completely out. Install

front screw. Use the remaining screw retained in step 3.
Tighten until snug. Snug rear screw again.

8. Make sure that all three O-rings are in their recesses,

and carefully push the rotary valve back into place.*
The large square notch must point up toward the elbow.
Replace the knob onto the rotary valve shaft, with the
wide flange pointing toward “Vacuum”. If necessary,
wiggle it slightly to fully seat the knob, then replace the
screw.
Do not overtighten.

9. Install the pressure pad onto the handle.

Note: Silverline

TM

metal pump must have handle screw-

hole, to install pressure pad.

*

If the O-rings have become dry, it helps to lightly lubricate
them with Silicone Oil or light grease.
Do Not Use Aerosol Lubricants.

DUAL CONVERTER MODEL 06895

and MODEL 04095

Advertising
This manual is related to the following products: