Re- assembly of the pumpset, Oil specifications – Mody Pumps MHMXP 6 X 12 User Manual

Page 9

Advertising
background image


RE- ASSEMBLY OF THE PUMPSET.


THE PUMP CAN BE RE- ASSEMBLED BY REVERSING THE ABOVE PROCEDURE. PLEASE HOWEVER
NOTE THE FOLLOWING:

• ALWAYS REPLACE ELASTOMER ELEMENTS.
• REPLACE LOCK WASHER DURING RE –ASSEMBLY.

• LIGHTLY OIL (DO NOT USE GREASE) OUTER SURFACE OF STATIONARY SEAT & PRESS IT

GENTLY INTO MOUNTING PLATE USING A SEAL PUSHER. NOTE WORK STATION SHOULD BE
ABSOLUTELY CLEAN NOT ALLOWING FOREIGN MATTER TO COME IN CONTACT WITH SEAL
FACES. MAKE SURE THE STATIONARY SEAT IS FLUSH AND STRAIGHT. THE O RING
SHOULD BE IN IT’S GROOVE AND NOT PINCHED.


• LIGHTLY OIL SHAFT(DO NOT USE GREASE) AND INNER SURFACE OF BELLOWS ON

ROTATING FACE. SLIDE ROTATING FACE ONTO SHAFT USING A SEAL PUSHER.



OIL SPECIFICATIONS


A) SUN OIL COMPANY – SUN FLEET REGULAR SAE 10W
B) SHELL – ROTELLA 10SAE 10W
C) STANDARD OIL COMPANY – SOHIO 62SAE 10W


PLEASE NOTE THE SEAL CHAMBER CONTAINS APPROX. 2.5 LITRES OF OIL
.